5
EN
T h e b a t t e r y i c o n i n d i c a t o r
a p p e a r s i n t h e
f o l l o w i n g a r e a s :
A R EA
M EA NI NG
Weather Forecast
Area
It displays
when the AC
adaptor is disconnected.
Temperature or
Humidity Area
Low battery in the main unit or
outdoor sensor for displayed
channel.
Wind Speed / Wind
Direction / Wind Chil
Area
Low battery in wind sensor.
UVI / Barometer /
Rainfall Area
Low battery in UV/Rain
sensor.
M O U NT I NG / P L A C I NG O F S ENS O R S
W I ND S ENS O R
Make sure the wind sensor is connected to the base
station before installation.
T o c h e c k t h e c o n n e c t i o n :
Press
S EL EC T
until the selected area icon is in the
top right display area.
• Wind speed: Gently rotate the wind vane and confirm
a numerical reading on the base station, e.g.
.
• Wind direction indicator. Move the direction of the
wind indication and verify the icon moves in the same
direction
.
The sensor should be positioned in an open area
away from trees or other obstructions.
T o i n s t a l l t h e w i n d s e n s o r :
a
b
Secure the sensor connector in the desired location:
a. Align the back of the sensor connector to an existing
pole. Secure in place by inserting the ends of the
U-bolt into the holes on the sensor connector and
securing it with washers and bolts.
OR
b. Insert 4 type A screws into the holes of the sensor
connector. Screw firmly into place, i.e., fence.
Slide wind vane onto the smaller end of the sensor
connector.
I M P O R T A NT
Make sure the wind sensor points to north
in order to record accurate readings.
T EM P ER A T U R E / H U M I D I T Y S ENS O R
Make sure the temperature/humidity sensor is
connected to the base station before installation.
T o c h e c k t h e c o n n e c t i o n :
1. Press
S EL EC T
until the selected area icon is in
the bottom left display area.
2. Press
U P / D O W N
to select channel 1
and verify
a numerical reading.
T o i n s t a l l t h e t e m p e r a t u r e / h u m i d i t y s e n s o r :
1.5 m (5 ft)
T I P
Ideal placements for the sensor would be in any
location on the exterior of the home at a height of not
more than 1.5 meters (5 feet) and which can shield it from
direct sunlight or wet conditions for an accurate reading.