Oregon Scientific Wireless Full Weather Station Kit WMR80 / WMR80A User Manual Download Page 7

7

EN

2.  Press  and  hold 

MODE 

to  activate  auto-scan.  The 

temperature  and  humidity  display  will  scroll  from 
indoor to ch1 through to ch3.

3.  Press any key to stop the auto-scan. 

 NOTE  

Channel 1 is used for the outdoor temperature 

and humidity sensor. Additional temperature and humidity 
sensors can use other channels.

WEATHER FORECAST

The weather display in the top part of the screen shows 
the current weather and the weather forecast for the next 
12-24 hours

 within a 30-50 km (19-31 mile) radius.

Weather Forecast Area

ICON

DESCRIPTION

Sunny

Partly cloudy

Cloudy

Rainy

Snowy

TEMPERATURE AND HUMIDITY

The  weather  station  displays  indoor  and  outdoor 
readings for:

1.   Temperature / relative humidity (current / maximum 

/ minimum)

2.   Trend line
3.   Wind chill (current / minimum) and dew point level 

(current / maximum / minimum)

The weather station can connect up to 

remote sensors. 

 NOTE 

 Channel 1 is dedicated for outdoor temperature 

and humidity. 
      shows which remote sensor’s data you are viewing.
      appears when indoor data is displayed.

The timestamp records the date and time when storing the 
temperature and humidity readings in memory.

To select the temperature measurement unit:

Press 

UNIT 

to select

 

°

C / 

°

F

.

 NOTE 

 

The unit of all temperature related displays will  be 

changed simultaneously.

To view temperature (Current / Min / Max temperature) 
readings:

1.   Press 

SELECT

 to navigate to the Temperature Area. 

 will show next to the Area.

2.   Press 

+ / -

 to select the channel.

3.   Press 

MIN / MAX

 to toggle between current / MAX / 

MIN displays.

To view humidity (Humidity, Dew point) readings:

1.   Press 

SELECT

 to navigate to the Humidity Area.   

will show next to the Area.

2.   Press 

+ / -

 to select the channel.

3.   Press 

MODE

  repeatedly  to  toggle  between  the 

humidity / dew point displays.

4.   Press 

MIN / MAX

 to toggle between current / MAX / 

MIN displays.

The  timestamp  is  displayed  accordingly  in  the  Clock 
Area.

To  clear  the  memories  and  timestamp  for  the 
temperature, humidity and dew point readings: 

In the Temperature or Humidity Area, press and hold 

MIN 

/ MAX

 to clear the readings.

  NOTE 

  The  dew  point  advises  at  what  temperature 

condensation will form. 

TEMPERATURE AND HUMIDITY TREND

The trend lines are shown next to the temperature and 
humidity readings. The trend is shown as follows:

RISING

STEADY

FALLING

WIND CHILL / DIRECTION / SPEED

The base station 
provides wind speed 
and wind direction 
information.  

To read the wind 
direction find the 
compass point the
is pointing to

.

The timestamp records the date and time when storing 
the wind speed readings.

To select the wind speed unit:

Press 

UNIT

 to switch between:

• 

Metres 

per second (

m / s

• 

Kilometers per hour (

kph

)

• 

Miles per hour (

mph

• 

Knots (

knots

)

WMR80_IM_EN_R1.indd   7

2008.7.1   7:11:43 PM

Summary of Contents for Wireless Full Weather Station Kit WMR80 / WMR80A

Page 1: ...ions 9 Precautions 10 About Oregon Scienti c 10 EU Declaration of Conformity 10 FCC Statement 10 INTRODUCTION Thank you for selecting the Oregon Scienti c Weather Station WMR80 WMR80A Thebasestationis...

Page 2: ...tivate backlight 3 MODE Switch between the different display modes settings set clock set altitude activate autoscan 2 x AA UM 3 1 5V batteries 4 x Screws Type B 1 x Rain Collector 4 UNIT Select unit...

Page 3: ...c pressure mmHg inHg or mb rainfall readings in hr or mm hr 4 UVI level indicator 5 Indicate past 24hrs rainfall is displayed 6 Indicate maximum UV is displayed 7 UVI barometric pressure rainfall hist...

Page 4: ...sensor connector to an existing pole Secure in place by inserting the ends of the U bolt into the holes on the sensor connector and securing it with washers and bolts OR b Insert 4 type A screws into...

Page 5: ...ch battery change 3 Remove the bre tape To ensure a level plane Put a few drops of water on the cross at the base of the funnel to check the horizontal level 1 2 3 4 Water will pool to the center of t...

Page 6: ...tion the base station should be placed on a at non metallic surface near a window in an upper oor of your home The antenna should be placed away from electrical appliances and not be moved around when...

Page 7: ...splays will be changed simultaneously To view temperature Current Min Max temperature readings 1 Press SELECT to navigate to the Temperature Area will show next to the Area 2 Press to select the chann...

Page 8: ...taken e g 2 hours ago 3 hours ago etc To view the UV Barometer Rainfall readings 1 Press SELECT to navigate to the UV Barometer Rainfall Area will show next to the Area 2 Press MODE to toggle between...

Page 9: ...range 50 C to 70 C 58 F to 158 F Operating range 0 C to 50 C 32 F to 122 F Accuracy 0 C 40 C 1 C 2 0 F 40 C 50 C 2 C 4 0 F Memory Current Min and Max temp Dew Point w Min and Max INDOOR RELATIVE HUMI...

Page 10: ...and would like to contact our Customer Care department directly please visit www2 oregonscienti c com service support asp For international inquiries please visit www2 oregonscienti c com about inter...

Page 11: ...th Ave Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 declare that the product Product No WMR80 WMR80A Product Name Wireless Full Weather Station Kit Manufacturer IDT Technology Limited Address...

Page 12: ...12 EN Wireless Full Weather Station Kit Model WMR80 WMR80A USER MANUAL WMR80_IM_EN_R1 indd 12 2008 7 1 7 11 53 PM...

Page 13: ...13 EN 2008 Oregon Scienti c All rights reserved 086L005677 044 t A L WMR80_IM_EN_R1 indd 13 2008 7 1 7 11 53 PM...

Reviews: