Oregon Scientific TREVISO BAR986HGA User Manual Download Page 20

EN

19

UV data is shown in the same area as the Barometer.
Press 

SELECT

 to navigate to the Barometer Area, then

press 

MODE

 to display the UV icon 

 and data.

Refer to the UVR138A User Manual for more

information and see below to learn about the new
additional UV features.

NEW ADDITIONAL UV FEATURES

UV EXPOSURE TIME COUNTDOWN

To set the exposure time countdown you need set to the
Skin Type and Sun Protection Factor (SPF) as follows:

1. Press 

SELECT

 to navigate to the Barometer Area,

then press 

MODE

 to select the UV display.

NOTE

2. Press 

CHANNEL

 to select user 1-4.

3. Press and hold 

MODE

  for 2 seconds to enter the

Skin Type Setting Mode of the selected user.

4. Press 

UP

 or 

DOWN

 to choose 1 of the 4 skin type

settings. Then press 

MODE

 to confirm and enter the

SPF Set Up Mode.

5. Press 

UP

 or 

DOWN

 to increase or decrease the 

SPF

value. Then press 

MODE

 to confirm and enter the

UV Exposure Time Countdown Setting Mode.

6. Press 

UP

 or 

DOWN

 to enable or disable countdown.

Press 

MODE

  to exit the UV Exposure Time

Countdown Mode and start the exposure time
countdown. The remaining user UV exposure time
will display and the 

 will flash.

7. When the countdown has reached "0", an alarm will

sound for 2 minutes. Press any button to turn the
alarm off. The 

 icon will flash for 2 minutes even

if you have stopped the alarm sound.

MAXIMUM / MINIMUM MEMORY FOR UVI

To view the maximum and minimum memory for UVI:

1. Press 

SELECT

 to navigate to the Barometer Area.

2. Press 

MODE

 to select the UV display.

3. Press 

MEMORY

 to show maximum, minimum and

current UVI readings.

4. Press and hold 

MEMORY

 for 2 seconds to clear the

UVI memory.

BAR988HGA English R5

9/18/04, 3:00 AM

19

Summary of Contents for TREVISO BAR986HGA

Page 1: ...TREVISO Sleek Weather Station Model BAR988HGA BAR986HGA USER MANUAL BAR988HGA English Cover R5 9 18 04 2 55 AM 1...

Page 2: ...Daily Alarm 15 Set Pre Alarm 16 Activate Alarm 16 Snooze 16 Barometer 16 View Barometer Area 17 Select Measurement Unit 17 View Barometer History 17 Bar Chart Display 17 Set Altitude 17 Weather Foreca...

Page 3: ...cklight 22 Reset System 22 Safety and Care 22 Warnings 22 Troubleshooting 23 Specifications 23 About Oregon Scientific 25 FCC Statement 25 Declaration of Conformity 26 BAR988HGA English R5 9 18 04 3 0...

Page 4: ...RTGR328NA Optional UV sensor UVR138A 6V AC adapter Batteries BAR988HGA BAR988HGAMain Unit RTGR328NA Remote Sensor BAR986HGA BAR988HGA Main unit RTGR328NA Remote Sensor UVR138A UV Sensor The THGR328N...

Page 5: ...HISTORY View historical barometer and UV readings 5 ALARM View alarm status set alarm 6 SNOOZE LIGHT Activate 8 minute snooze or backlight 7 SELECT Switch Areas 8 CHANNEL Switch remote sensor display...

Page 6: ...AC adaptor socket 4 C F switch in battery compartment 5 RESET button in battery compartment 6 mb inHg switch in battery compartment You can adjust the angle of the clock display as shown below BACK V...

Page 7: ...idity Comfort Zone Area Readings and trend lines comfort zone sensor channel number 3 UVI Barometer Area UV level and barometric pressure bar chart UV Index and barometric readings 4 Clock Alarm Calen...

Page 8: ...rature Humidity Comfort Zone Area 1 Selected Area icon 2 Temperature trend 3 Channel number 1 5 reception status 4 Low battery icon for remote sensor 5 Humidity trend 6 MAX MIN temperature 7 Temperatu...

Page 9: ...exposure 10 User skin type for UV exposure 11 User no for UV Mode or hour history for UV Barometric pressure reading 12 Altitude barometric pressure UVI reading Clock Alarm Calendar Area 1 Pre Alarm...

Page 10: ...E SENSOR RTGR328NA 1 LCD display 2 LED status indicator 3 Ventilation duct 1 Signal reception 2 US time zone 3 Channel number 4 Low battery icon 5 Time 6 Temp C or F 7 Humidity 8 Temp Humidity BAR988H...

Page 11: ...he battery compartment For best results install batteries in the remote sensor before the main unit Press RESET after each battery change To install the main unit batteries 1 Wall mount 2 CHANNEL swit...

Page 12: ...cted Area 2 Most Areas have alternate display options for example Clock Alarm or Barometer UVI Press MODE to switch options or ALARM to switch between clock and alarm 3 Press and hold MODE for 2 secon...

Page 13: ...or close to the main unit during cold winter months as below freezing temperatures may affect battery performance and signal transmission The RTGR328NA Sensor collects and transmits temperature and hu...

Page 14: ...r 2 seconds To search for the UV sensor press SELECT to navigate to the UVI Barometer Area will show next to the Area Then press and hold MEMORY and CHANNEL for 2 seconds The UV sensor is an optional...

Page 15: ...ls work together To force a manual search for atomic clock reception press and hold SEARCH on the sensor RTGR328NA for 2 seconds TURN ATOMIC CLOCK ON OFF If you wish to manually set the clock you must...

Page 16: ...another US time zone select an hour offset accordingly The time zone options and their related hour offset times are Pacific 8 Mountain 7 Central 6 and Eastern 5 NOTE The language options are E Engli...

Page 17: ...Alarm will sound BEFORE the Daily Alarm The Pre Alarm is automatically activated when you select a time NOTE 5 Press ALARM to confirm shows when the Pre Alarm is set The Daily Alarm will NOT function...

Page 18: ...ORY Navigate to the Barometer Area Then press HISTORY repeatedly to scroll through the measurements The number shown in the HR box indicates how long ago each measurement was taken e g 2 hours ago 3 h...

Page 19: ...1 Sensor records a temperature of 35 6 F 2 C or lower the RAINY icon becomes SNOWY UV MEASUREMENT OPTIONAL SENSOR The UVR138A Ultra Violet Radiation Sensor is included with the BAR986HGA and is availa...

Page 20: ...ress MODE to confirm and enter the SPF Set Up Mode 5 Press UP or DOWN to increase or decrease the SPF value Then press MODE to confirm and enter the UV Exposure Time Countdown Setting Mode 6 Press UP...

Page 21: ...is below NOTE SELECT MEASUREMENT UNIT Slide the C F switch inside the clock battery compartment to the setting you want SELECT SENSOR CHANNEL Press CHANNEL to switch between sensors 1 5 The house ico...

Page 22: ...77 F 20 25 C 40 70 DRY Any 40 This information is shown in the Humidity Area when the current measurement is displayed NOTE To display the Heat Index 1 Press SELECT to navigate to the TemperatureArea...

Page 23: ...handled properly Oregon Scientific will not be responsible for any deviations in the usage of the device from those specified in the user instructions or any unapproved alterations or repairs of the p...

Page 24: ...F to 140 F 20 C to 60 C Resolution 0 2 F 0 1 C Comfort 68 F to 77 F 20 C to 25 C Memory Min Max Relative Humidity Range 25 to 95 Resolution 1 PROBLEM SYMPTOM REMEDY Barometer Strange readings Set alti...

Page 25: ...te Channel No 1 2 3 4 or 5 Unit C or F Atomic Clock Synchronization Auto or disabled Clock display HH MM SS Hour format 12hr AM PM or 24hr Calendar DD MM or MM DD Day of the week in 1 of 5 languages E...

Page 26: ...ce may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Changes or modifications to this unit not expres...

Page 27: ...for this product for all inquiries instead We Name Oregon Scientific Inc Address 19861 SW 95th Place Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 Fax No 1 503 684 8883 declare that the produc...

Page 28: ...2004 Oregon Scientific All rights reserved 086 000000 000 BAR988HGA English Back R5 9 18 04 1 24 AM 1...

Reviews: