background image

9

EN

2. Press 

 to set the temperature or humidity limit. Each press

will increase increments by 

1

 degree or percentage. Press and

hold the button for a rapid-scrolling sequence by increments
of 

5

.

Note:

The 

temperature

 range is from -50

°

C (-58

°

F) to +70

°

C (158

°

F).

If this is the first time you set the limits, the lower limit will start
from -50

°

C (-58

°

F) and the upper limit +70

°

C (158

°

F). Otherwise,

the reading will start from the temperature last selected.

The 

humidity

 range is from 2% to 98%.

If this is the first time you set the limits, the lower limit will start
from 2% and the upper limit 98% Otherwise, the reading will start
from the humidity last selected.

3. Repeat the steps to set the upper humidity setting and the lower

temperature and humidity settings.

4. When finished, press 

HI/LO

 to set another limit or wait 16-

seconds and the unit will automatically return to the normal
display. The respective HI, LO or both indicators will light up
to signify the status of the alarm.

If in another 

channel-1

 other than channel one is selected, when the

alarm activates the display will switch to channel-1 and the display
will flash. If left untouched, the alarm will activate 

for 1-minute

.

P r e s s  

I N / C H A N N E L

,  

M E M O RY

,  

[HI/LO], [

], [ON/OFF]

(TEMP % RH AL)

to momentarily stop the alarm. The alarm will activate again if the
value continues exceeds the set limit.

To clear the memory:

Press and hold 

MEMORY 

for 2-seconds.

If you press 

MEMORY 

now, the maximum and minimum

temperatures will have the same values as the current ones until
different readings are recorded.

HOW TO USE CHANNEL-1

TEMPERATURE/HUMIDITY ALARM

Upper and lower temperature and humidity limits for channel-1
can be set so that an alarm activates when the limits are exceeded.

The high and low temperature and humidity displays are selected
by sequentially pressing 

HI/LO

.

The high-low displays are as follows:

                 Sequence

Respective Display

Pressing 

HI/LO

 once

Enters HI temperature display

Pressing 

HI/LO

 twice

Enters HI humidity display

Pressing 

HI/LO

 third time

Enters LO temperature display

Pressing 

HI/LO

 fourth time

Enters LO humidity display

To set a high or low temperature or humidity alarm:

1. Press 

HI/LO

, channel-1 will be displayed.

RMR132HG_M_EN_R01

8/13/04, 12:30 PM

9

Summary of Contents for RMR132HG

Page 1: ...lected and transmitted by the remote unit The main unit can support up to 3 remote units The main unit is capable of keeping track of the maximum and minimum recordings of different sites And no wire installation is required and the RMR132HG operates at 433MHz As for the calendar clock it is radio controlled It automatically synchronizes its current time and date when it is brought within an appro...

Page 2: ...AY Facilitates easy reading of remote and indoors temperature humidity readings and calendar clock B BATTERY LOW INDICATOR Activates when the remote sensor or main unit battery power is low C RADIO RECEPTION SIGNAL Indicates the condition of radio reception D IN CHANNEL BUTTON Selects remote sensor channels E SET MODE BUTTON Toggles between display modes and confirms entry while setting the values...

Page 3: ...gnates the remote unit Channel 1 Channel 2 or Channel 3 E RESET Returns all settings to default values F BATTERY COMPARTMENT Accommodates two 2 AAA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGIN For best operation 1 Assign different channels to different remote units...

Page 4: ...unit after installing batteries This will ensure easier synchronization between the transmission and reception of signals 4 Position the remote unit and main unit within effective transmission range which in usual circumstances is 20 to 30 meters Note that the effective range is vastly affected by the building materials and where the main and remote units are positioned Try various set ups for bes...

Page 5: ...unit it comes with a wall mount holder and a removable stand Use either to hold the unit in place Main unit Wall mount Table Stand 3 Replace the battery compartment door LOW BATTERY WARNING When it is time to replace batteries the respective low battery indicator will show up when the respective channel is selected The battery level of the main unit will be shown on the indoor temperature window w...

Page 6: ...led Upon successful reception the individual channel temperature reading will be displayed on the top line and the respective humidity reading on the bottom line The main unit will automatically update its readings at about 40 second intervals If no signals are received blanks will be displayed and the kinetic wave icon will not show To force a signal search Press and hold IN CHANNEL MEMORY for 2 ...

Page 7: ...ll be displayed until further readings are successfully searched Check the remote sensor to ensure that it is secure and that the correct channel has been selected Optionally press and hold IN CHANNEL MEMORY for 2 seconds to enforce a search HOW TO READ THE KINETIC WAVE DISPLAY The kinetic wave display shows the signal receiving status of the main unit There are three possible forms THE COMFORT LE...

Page 8: ...adings will automatically be stored in the memory To display the maximum and minimum display memory 1 Select the channel to be checked 2 Press MEMORY once to display the maximum temperature and again the minimum temperature The respective indicators MAX or MIN will be displayed TEMPERATURE AND HUMIDITY TREND INDICATORS The temperature trend and humidity trend indicators show the trends of collecte...

Page 9: ...hannel one is selected when the alarm activates the display will switch to channel 1 and the display will flash If left untouched the alarm will activate for 1 minute Press IN CHANNEL MEMORY HI LO ON OFF TEMP RH AL to momentarily stop the alarm The alarm will activate again if the value continues exceeds the set limit To clear the memory Press and hold MEMORY for 2 seconds If you press MEMORY now ...

Page 10: ...our display modes in the sequence of MODE 1 Local Time Hour Minute Second Day Month Note If a second limit is passed while an alarm is active the first alarm will complete its 1 minute cycle and the alarm will continue to activate for a second minute cycle to indicate that a second limit has been surpassed To disable an alarm 1 Enter the setting mode by pressing HI LO 2 Then press AL ON OFF The al...

Page 11: ...s calendar clock once it is brought within range of the Frankfurt DCF77 radio signal When the RMR132HG is within range its radio control mechanism will override all manual settings When the unit is receiving radio signal the radio reception signal will start to blink A complete reception generally takes about 2 to 10 minutes depending on the strength of the radio signal When the reception is compl...

Page 12: ...hat order Day of week is the usual sequence of Monday through Sunday For the second time zone which is indicated by the ZONE ICON enter the hour offset using the or buttons and the RMR132HG will calculate the second time accordingly If there is an item you do not wish to change simply press SET MODE to bypass the item When you are done press SET MODE to exit The display will return to the mode las...

Page 13: ... the unit to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and distorted parts 4 Do not tamper with the unit s internal components Doing so will invalidate the warranty on the unit and may cause unnecessary damage The unit contains no user serviceable parts 5 Only use fresh batteries as specified in the user manual D...

Page 14: ...142 x 84 x 24 5 mm LxWxT Remote sensing unit 92 x 60 x 20 mm LxWxT ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products such as digital cameras MP3 players children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and confer ence phones The website also includes contact infor...

Page 15: ... 1 b of the R TTE Directive Applied Standards ETSI EN 301 489 1 3 Ver 1 4 1 2002 08 Efficient use of radio frequency spectrum Article 3 2 of the R TTE Directive Applied Standards ETSI EN 300 220 3 Ver1 1 1 2000 09 Additional information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EC the EMC Directive 89 336 EC and carries the CE marking accordingly Carmel...

Reviews: