Oregon Scientific RMR112 User Manual Download Page 7

7

GB

automatically converted to the chosen one of the main unit.

CALENDAR CLOCK DISPLAY MODES

The RMR112 supports four display modes in the sequence of:

MODE 1.  Hour-Minute-Second (of local time)

--------------------------------------------
Day-Month (of local time)

MODE 2.  Hour-Minute-Day of the Week (of local time)

-------------------------------------------------------
Day-Month (of local time)

MODE 3.  Hour-Minute-Day of the Week (of local time)

-------------------------------------------------------
Hour-Minute (of second time zone)

MODE 4.  Hour-Minute-Day of the Week (of second time zone)

----------------------------------------------------------------
Day-Month (of second time zone)

Each press on the MODE button will toggle the display in the above
order.

Note: The bottom line of the display will be replaced by the alarm

time if the [24HR 

 OFF] button is pressed.

ABOUT RADIO RECEPTION

The RMR112 is designed to automatically synchronize its calen-
dar clock once it is brought within range of the Frankfurt DCF77
radio signal.

When the RMR112 is within range, its radio-control mechanism
will override all manual settings.

When the unit is receiving radio signal, the radio reception signal
will start to blink. A complete reception generally takes about 2 to
10 minutes, depending on the strength of the radio signal.

When the reception is complete, the radio reception signal will
stop blinking. The strength of the reception for the last full hour
will be indicated.

Summary of Contents for RMR112

Page 1: ...collected and transmitted by the remote unit The main unit can support up to three remote units The main unit is capable of keeping track of the maximum and minimum temperature of different sites And...

Page 2: ...play F RADIO RECEPTION SIGNAL Indicates the condition of radio reception G UP BUTTON Advances the value of a setting H DOWN BUTTON Decreases the value of a setting I ALARM AL ON OFF BUTTON Enables or...

Page 3: ...se as possible next to the remote unit reset the main unit after installing batteries This will ensure easier synchronization between the transmission and reception of signals 4 Position the remote un...

Page 4: ...ount Table Stand Note that once a channel is assigned to a remote unit you can only change it by removing the batteries or resetting the unit BATTERY INSTALLATION MAIN UNIT 1 Slide open the battery co...

Page 5: ...lar remote site Three trends rising steady and falling will be shown THE RESET BUTTON This button is only used when the unit is operating in an unfavor able way or malfunctioning Use a blunt stylus to...

Page 6: ...RY to enforce an immediate search If that fails check 1 The remote unit of that channel is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note When the tempe...

Page 7: ...above order Note The bottom line of the display will be replaced by the alarm time if the 24HR OFF button is pressed ABOUT RADIO RECEPTION The RMR112 is designed to automatically synchronize its cale...

Page 8: ...econd time zone Note that the time and date are displayed in 24 HOUR clock and DAY MONTH format respectively For display language you can choose among English E German D French F and Italian I in that...

Page 9: ...satisfactory service if you handle it carefully Here are a few precautions 1 Do not immerse the unit in water 2 Do not clean the unit with abrasive or corrosive materials They may scratch the plastic...

Page 10: ...MHz No of Remote unit Maximum of 3 RF Transmission Range Maximum 30 meters Temperature sensing cycle around 30 seconds Radio Controlled Clock Maintime set and synchronized by Radio Signal DCF77 for C...

Page 11: ...e and that the following standard s has been applied Electromagnetic compatibility Article 3 1 b of the R TTE Directive Applied standards ETS 300 683 1997 Efficient use of the radio frequency spectrum...

Reviews: