Outdoor measurements are collected by the remote
unit.

Temperature is give at the top; humidity is below.

VIEW MIN / MAX / CURRENT MEASUREMENTS

Press 

SELECT 

3 times until the Temperature and

Humidity Areas flash. Press 

UP

 or 

DOWN

 to scan the

readings.

CLEAR MIN / MAX RECORDS

While viewing Min/Max records, press and hold 

UP

 or

DOWN

 for 2 seconds until a beep sounds. This clears

the previous measurements from the memory.

SELECT REMOTE UNIT CHANNEL

While in the Temperature / Humidity Mode, press

CHANNEL

 to switch between CH 1, 2, or 3, or press

and hold 

CHANNEL

 for 2 seconds to enter Auto scan

mode. If only 1 remote unit is in use, you will not be able
to change channels or select Auto. If you select “Auto”,
the channel will change every 3 seconds.
To deactivate, press and hold 

CHANNEL

 for

2 seconds again.

SENSOR SEARCHING

If there is no remote unit signal, the temperature and
humidity measurements will be blank. Check the remote
unit batteries, or press and hold 

UP

 and 

DOWN

 for

2 seconds to search for the remote unit(s).

PS M01 English R17 op

7/24/03, 10:57 AM

15

Black

Summary of Contents for PS-M01

Page 1: ...EN Full Weather Station with Radio Controlled Clock Model PS M01 PS M01U User Manual PS M01 English Cover R7 op 7 24 03 10 42 AM 1 Black...

Page 2: ...ween modes 8 Change settings 9 Remote unit set up 9 Clock 10 Alarm 11 Calendar 12 Moon phase 12 Barometer 13 Weather forecast 14 Temperature humidity 14 Backlight 17 Reset system 18 Safety and care 18...

Page 3: ...k PS M01 PS M01U This powerful device bundles time keeping alarm indoor and wireless outdoor temperature and humidity monitoring and weather forecasting into a single tool you can use from the conveni...

Page 4: ...EN 3 DESCRIPTIONS 1 Snooze Light button 2 Light sensor PRODUCT OVERVIEW TOP VIEW 2 1 PS M01 English R17 op 7 24 03 10 57 AM 3 Black...

Page 5: ...DESCRIPTIONS 1 Low battery icon 2 Clock 3 Barometer 4 Weather forecast 5 Moon phase 6 Calendar 7 Temperature and humidity 8 Alarm LCD DISPLAY 1 2 3 4 5 6 7 8 PS M01 English R17 op 7 24 03 10 57 AM 4 B...

Page 6: ...modes change settings 2 Up increase setting activate auto synch 3 Down decrease setting deactivate auto synch 4 Channel switch remote unit 5 Alarm activate deactivate alarm BACK VIEW 4 5 1 2 3 PS M01...

Page 7: ...ND SIDE VIEW DESCRIPTIONS 1 Battery compartment 2 Backlight switch 3 Reset button 4 Light sensitvity knob 5 DC Power input jack AC power adapter not shown NOTE 3 1 5 4 PS M01 English R17 op 7 24 03 10...

Page 8: ...2 Low battery icon 3 Humidity Trend Comfort Level display 4 C F switch 5 Channel switch 6 Reset button 7 Battery compartment 8 Wall Mount hole 9 Battery compartment lid REMOTE UNIT 5 4 6 7 8 9 1 2 3 P...

Page 9: ...d mode will flash The display will stop flashing if no key is pressed within 5 seconds NOTE NOTE GETTING STARTED BATTERIES Batteries for the remote and main units are supplied with this product Replac...

Page 10: ...one remote unit be sure to select a different channel number for each unit NOTE INSTALLATION Mount the remote unit on a flat surface using the recess holes on the back of the unit For best results Be...

Page 11: ...to complete Once complete the icon will stop blinking For best results place the unit away from metal or electrical objects and near a window with a clear view to the sky TO DISABLE OR ENABLE AUTO SY...

Page 12: ...emporarily disable the alarm for 8 minutes The alarm icon will blink while Snooze is activated SET OR CHANGE THE CLOCK 1 Press SELECT to switch to the Clock Mode The time will flash 2 Press and hold S...

Page 13: ...until the calendar area flashes 2 Press and hold SELECT for 2 seconds to enter the calendar setting mode 3 Select the year month date and language Press UP or DOWN to change the setting Press SELECT t...

Page 14: ...the past 24 hours to provide the weather forecast 14 and a trend line showing the direction of barometric change Barometric changes are measured by the main indoor unit BAROMETRIC TREND The barometri...

Page 15: ...the unit of measurement mb hPa or inHg Press UP or DOWN to change the setting Press SELECT to confirm WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 to 50 km 19...

Page 16: ...E UNIT CHANNEL While in the Temperature Humidity Mode press CHANNEL to switch between CH 1 2 or 3 or press and hold CHANNEL for 2 seconds to enter Auto scan mode If only 1 remote unit is in use you wi...

Page 17: ...l and does not affect the general performance of the product Reception will automatically resume once the interference ends COMFORT ZONE The indoor and outdoor comfort zones are shown for the followin...

Page 18: ...Press SELECT to confirm BACKLIGHT Press SNOOZE LIGHT to illuminate the backlight for 5 seconds CONTINUOUS BACKLIGHT The AC power adapter must be plugged in to use this feature 8 1 The BACKLIGHT switc...

Page 19: ...e main and remote units Press these buttons with the tip of a blunt object such as a ball point pen whenever you change the batteries or whenever performance is not behaving as expected e g unable to...

Page 20: ...er with the internal components Do not mix new and old batteries or batteries of different types Do not use rechargeable batteries with this product Remove the batteries if storing this product for a...

Page 21: ...17 TROUBLESHOOTING Check here before contacting our customer service department Cannot change channel Check sensors Only one sensor is working 15 Problem Symptom Remedy 2 Press RESET All memory items...

Page 22: ...ms with battery Temperature Unit C or F Range Main unit 5 C to 50 C 23 F to 122 F Remote Unit 20 C to 60 C 4 F to 140 F If it still fails you may be too far from a signal Problem Symptom Remedy 4 Plac...

Page 23: ...nimum maximum Trend 3 change Barometer Unit mb hPa or inHg Range 500 to 1050 mb 14 77 to 31 01 inHg Resolution 1mb 0 03 inHg Altitude 100 to 2500 meters 328 to 8202 feet Display Rainy cloudy partly cl...

Page 24: ...A 1 5V alkaline batteries back up AC DC 6V power adapter for normal operation and continuous backlight Remote unit 2 x UM 4 AAA 1 5V alkaline batteries ADDITIONAL RESOURCES Visit our website www orego...

Page 25: ...This product contains the approved transmitter module TX 07 and complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directives if used for its intended use and that the follow...

Reviews: