Oregon Scientific EB833 User Manual Download Page 12

EN

12

2. Press [TIME] to view the 

Current Date / Month

Display.

Display shows:

3. Press [TIME] again to view the 

Alarm Time Display

Display shows:

4. Press [TIME] again to view the 

Timer Display

Display shows:

GENERAL OPERATION OF THE TIME AND
DATE FUNCTIONS

The EB833 has a Time and Date Mode. This mode also
includes a count-up timer and daily wakeup alarm.

The Time and Date Mode only affects the third line of the
LCD.

To View Different Time and Date Mode displays:

1. Enter Normal Altimeter Display or Normal Barometer

Display to view current time.

Normal Time Display

The first display in Time and Date Mode.

NOTE

-

Normal Time Display is the third line of either the
Normal Altitude Display or Normal Barometer Display.

-

Only the third line of the LCD will change in Time
Date Mode.

Display shows:

NORMAL TIME DISPLAY

CURRENT
TEMPERATURE

CURRENT TIME

 TIMER DISPLAY

CURRENT
TEMPERATURE

COUNT-UP TIME

ALARM TIME DISPLAY

CURRENT
TEMPERATURE

ALARM TIME

DATE MONTH DISPLAY

CURRENT
TEMPERATURE

CURRENT DATE / MONTH

EB833(EN3)

8/31/04, 3:40 PM

12

Summary of Contents for EB833

Page 1: ...Notes On Altimeter Functions 9 General Operation Of Barometer And Weather Forecast Functions 9 Barometric Pressure Calibration 10 Units Of Measurement For Barometric Pressure 10 Altimeter Barometer wi...

Page 2: ...33 has three primary functions 1 Altimeter Functions related to altitude measurement 2 Barometer and Weather Forecast Device Functions related to weather forecasts and atmospheric pressure 3 Clock Cal...

Page 3: ...to a rucksack or belt FULL SEGMENT DISPLAY Hand Grips Rubberized grips that prevent the unit from being accidentally dropped Wall Mount Bracket to mount unit to wall or vertical surfice INSTALLING AN...

Page 4: ...st time it will automatically enter the Normal Altimeter Display Display shows Follow these steps to install or replace batteries 1 Open battery cover located at the back of the unit by removing screw...

Page 5: ...return to the Normal Altitude display CHANGE IN ALTITUDE ALTITUDE MIN MEMORY DISPLAY MINIMUM ALTITUDE REACHED ACCUMULATIVE VERTICAL DECENT MEMORY ACCUMULATIVE VERTICAL DECENT ICON CHANGE IN ALTITUDE A...

Page 6: ...ne or post is 1500m At this point set the current altitude to 1500m NOTE The unit will return to Normal Altimeter Display if no buttons are pressed for one minute during the calibration sequence UNITS...

Page 7: ...in altitude digits will reset to 0 m ft 4 Press ALT and proceed to the maximum or minimum height reached memory The subsequent maximum or minimum altitude digits flash ALTITUDE HISTORY DISPLAY In add...

Page 8: ...d intervals 3 Press and hold for about 2 seconds The Altitude Sampling Rate will decrease to 15 minute intervals 5 Press or the memory resets to the current actual altitude 6 Press ALT andproceedtothe...

Page 9: ...nit s displayed altitude against known actual altitudes If necessary manually calibrate the altitude to maintain correct altitude readings GENERAL OPERATION OF THE BAROMETER AND WEATHER FORECAST FUNCT...

Page 10: ...le source like a weather station the barometer can be calibrated To calibrate the barometric function 1 Enter Normal Barometric Display 2 Simultaneously press and hold BARO and TIME for about 2 second...

Page 11: ...periods it is advised to keep the unit in Barometer Mode In addition to maximizing the weather forecasting capabilities the unit requires less power to function Subsequently battery life may be extend...

Page 12: ...LCD To View Different Time and Date Mode displays 1 EnterNormalAltimeterDisplayorNormalBarometer Display to view current time Normal Time Display The first display in Time and Date Mode NOTE Normal Ti...

Page 13: ...or to select between 12 hour or 24 hour time format 10 Press TIME again the hour digit starts flashing 11 Press or to increase decrease the hour digit 12 Press TIME again minute digits start flashing...

Page 14: ...s the timer starts counting 3 Press again the timer stops To start the timer again without clearing the elapsed time press 4 To reset the timer to 0 press to stop the timer and then press TEMPERATURE...

Page 15: ...or distorted parts 4 Do not tamper with the unit s internal components Doing so will terminate the unit s warranty and may causedamage Theunitcontainsnouser serviceable parts 5 Only use new batteries...

Page 16: ...onds Resolution 1 second CAUTION The content of this manual is subject to change without further notice Due to printing limitations the displays shown in this manual may differ from the actual display...

Page 17: ...s contact information for our customer care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the information you need on o...

Page 18: ...EN 18 2004 Oregon Scientific All rights reserved P N 086 001667 234 EB833 EN3 8 31 04 3 40 PM 18...

Page 19: ...EN 19 Altimeter Barometer With Weather Forecasts And Clock Calendar Model EB833 User Manual EB833 EN3 8 31 04 3 40 PM 19...

Reviews: