background image

 

BLE Upper Arm Blood Pressure Monitor 

Model: BPU321 

User Manual 

CONTENTS 

Introduction ........................................................ 1 

Package contents .............................................. 2 

Accessories .............................................. 2 

Product view / Key features ............................... 2 

Setting up the monitor ........................................ 3 

Assemble the unit ..................................... 3 

Installing and replacing the batteries ........ 3 

Monitor settings .................................................. 3 

Positioning the arm cuff…………………………..4 

Preparing to take blood pressure measurement.4 

Taking a measurement ...................................... 5 

Understanding the reading ................................. 5 

Display ...................................................... 5 

Hypertension ............................................ 6 

Irregular heartbeat / Arrhythmia ................ 6 

Movement / reading error ......................... 6 

Voice announcement ................................ 6 

View records ...................................................... 6 

Recalling measurements stored   

in memory ................................................. 7 

Clear records ..................................................... 7 

Deleting a single record ............................ 7 

Deleting all records ................................... 7 

Data transmission .............................................. 8 

Manually send data .................................. 8 

Unique Device ID ..................................... 8 

Application………………………………………….9 

Troubleshooting ................................................. 9 

 

Safety and Care Instructions .............................. 9 

Useful reference ............................................... 10 

About blood pressure .............................. 10 

How the blood pressure monitor works ... 11 

Specifications ................................................... 11 

About Oregon Scientific .................................... 12 

Information about the CE Mark ......................... 12 

Symbol description(s) ....................................... 12 

EU - Declaration of Conformi

ty………………….12 

FCC S

tatement…………………………………13 

Blood Pressure Log Book .......................... 

……13 

 

INTRODUCTION 

Thank you for selecting the Oregon Scientific

TM

 

BLE Upper Arm Blood Pressure Monitor 

(BPU321). The BPU321 features multi-language 

voice announcement and playback of blood 

pressure measurements for added convenience 

and has been designed to provide you with many 

years of reliable service. The monitor can help 

you measure and track the following metrics: 

 

Systolic pressure 

 

Diastolic pressure 

 

Average morning / evening blood pressure 

 

Heart rate 

The monitor is able to store up to 100 

measurements per user (maximum 2 users) and 

equipped with the latest Bluetooth Smart 

technology to achieve reliable transmission 

linkage with a mobile device or tablet PC that is 

with the logo 

and corresponding 

application. From now on, you can easily track 

your health on a daily basis. 

 

Readings taken by the blood pressure monitor 

are equivalent to those obtained by a trained 

observer using the cuff and stethoscope 

Summary of Contents for BPU321

Page 1: ...entific 12 Information about the CE Mark 12 Symbol description s 12 EU Declaration of Conformity 12 FCC Statement 13 Blood Pressure Log Book 13 INTRODUCTION Thank you for selecting the Oregon Scientific TM BLE Upper Arm Blood Pressure Monitor BPU321 The BPU321 features multi language voice announcement and playback of blood pressure measurements for added convenience and has been designed to provi...

Page 2: ...nformation please contact your local retailer Replacement Arm cuff Storage pouch 6V adaptor Features and accessories will not be available in all countries PRODUCT VIEW KEY FEATURES A start taking blood pressure for user 1 view user 1 measurement records view additional older records increase value of the setting toggle setting options B turn monitor on off enter setting mode confirm settings star...

Page 3: ...Align the cover flat against the battery compartment and then slide it upwards Above diagram displays 1 Adaptor outlet 2 Battery compartment Flashing indicates monitor batteries are low Replace batteries promptly to ensure accurate readings Replace all the batteries at the same time it is dangerous to mix old and new batteries Contact your local waste disposal authority for instructions on how to ...

Page 4: ...hysician has diagnosed you with poor circulation in your left arm use your right arm 1 Choose the position from which you wish to measure sitting or lying down 2 Roll or push up your sleeve to expose the skin 3 Put arm through the cuff loop 4 Place cuff about an inch 1 2 cm above your elbow Use cushions or other supports if necessary to adjust The air tube should run down between the inside of you...

Page 5: ...efore starting a measurement 1 Relax your arm 2 Press to turn on the unit 3 Select user then a voice prompts you to sit in the correct position and to remain still Button User Memory Guest No records stored 1 Record stored under User 1 2 Record stored under User 2 4 Arm cuff will begin inflating automatically Digits will appear on the screen 5 Once the pressure reaches a certain level it will slow...

Page 6: ...are steady at regular intervals An irregular heartbeat is one where there is a variance and the intervals vary If an irregular heart beat has been detected during the measurement will be displayed We highly recommend you consult your physician MOVEMENT READING ERROR If Err 1 is displayed please loosen the arm cuff and relax 2 3 minutes before taking another measurement Refer again to Preparing to ...

Page 7: ... the corresponding user button repeatedly or to see additional records average morning evening if available or next record TIP Press and hold corresponding user button or to quickly toggle through all the entries To alternate between different user s records Press or CLEAR RECORDS When memory is full flashes Apart from deleting an entire measurement history there is also an option to delete the la...

Page 8: ...lly At midnight everyday MANUALLY SEND DATA To prevent records from being erased we recommend users send data to their mobile device periodically When viewing records Press and hold or Successful transmission Unsuccessful transmission 8 The screen display will turn off once synchronization attempt whether successful or not has been completed Synchronizing status indicator light located above the t...

Page 9: ...ot confuse self monitoring with self diagnosis This unit allows you to monitor your blood pressure Do not begin or end medical treatment based solely on the measurements of this device Consult a physician for treatment advice If you are taking medication consult your physician to determine the most appropriate time to measure your blood pressure Never change a prescribed medication without consult...

Page 10: ...What are systolic pressure and diastolic pressure When ventricles contract and pump blood out of the heart blood pressure reaches its maximum value This highest pressure in the cycle is known as systolic pressure When the heart relaxes between heartbeats the lowest blood pressure is diastolic pressure Why measure your blood pressure Blood pressure measurement can highly reflect one s health condit...

Page 11: ... HOW THE BLOOD PRESSURE MONITOR WORKS This product uses the Oscillometric Measuring method to detect your blood pressure Before every measurement the unit establishes a zero pressure equivalent to the air pressure Then it starts inflating the arm cuff to 180mmHg or higher until it senses that it has blocked your blood in the artery After that the deflation process starts during which time the unit...

Page 12: ...1 General requirements and EN1060 3 Non invasive sphygmomanometers Part3 Supplementary requirements for electromechanical blood pressure measuring systems The CE mark further indicates that this blood pressure monitor meets the general requirements for electronic products as regards to resistance to electromagnetic interference Malfunctioning may however occur in the proximity of extremely strong ...

Page 13: ...ry to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING This equipment complies with FCC RF radiation e...

Page 14: ...interference received including interference that may cause undesired operation ...

Reviews: