background image

PRECAUTIONS

• 

Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.

• 

Do not cover the ventilation holes with any items such as 
newspapers, curtains etc.

• 

Do not immerse the unit in water. If you spill liquid over 
it, dry it immediately with a soft, lint-free cloth.

• 

Do  not  clean  the  unit  with  abrasive  or  corrosive 
materials. 

• 

Do not tamper with the unit’s internal components. This 
invalidates the warranty.

• 

Only  use  fresh  batteries.  Do  not  mix  new  and  old 
batteries.

• 

Images shown in this manual may differ from the actual 
display.

• 

When  disposing  of  this  product,  ensure  it  is  collected 
separately  for  special  treatment,  and  not  as  normal 
household waste.

• 

Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  finish  for  which  Oregon 
Scientific  will  not  be  responsible.  Consult  the  furniture 
manufacturer's care instructions for information.

• 

The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.

• 

Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.  Collection  of  such  waste  separately  for  special 
treatment is necessary.

• 

Please  note  that  some  units  are  equipped  with  a 
battery  safety  strip.  Remove  the  strip  from  the  battery 
compartment before first use.

 NOTE  

The technical specifications for this product and the 

contents of the user manual are subject to change without 
notice.

 NOTE 

 Features and accessories will not be available in all 

countries.  For  more  information,  please  contact  your  local 
retailer.

SPECIFICATIONS

TYPE

DESCRIPTION

MAIN UNIT

L x W x H

94 x 46 x 160 mm
(3.7 x 1.8 x 6.3 in)

Weight

222g (7.8 oz) without battery 

Temperature range

-5°C to 50°C (23°F to 122°F)

Signal frequency

433 MHz

Humidity range

25% - 95%

Power

3 x UM-3 (AA) 1.5 V batteries

REMOTE UNIT (THGN132N)

L x W x H

96 x 50 x 22 mm  

 

(3.78 x 1.97 x 0.87 in)

Weight

62 g (2.22 ounces)

Transmission range

30 m (98 ft) unobstructed

Temperature range

-20°C to 60°C (-4°F to 140°F)

Humidity range

25% - 95%

Power

1 x UM-3 (AA) 1.5 V batteries

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more 
about  Oregon  Scientific  products.  If  you’re  in  the  US  and 
would like to contact our Customer Care department directly, 
please visit:
www2.oregonscientific.com/service/support.asp

For international inquiries, please visit: 
www2.oregonscientific.com/about/international.asp

EU-DECLARTION OF CONFORMITY

Hereby,  Oregon  Scientific,  declares  that  this  Solar  Weather 
Station  with  Outdoor  Hygrometer  (Model:  BAR806HG  / 
BAR806HGA) is in compliance with the essential requirements 
and other relevant provisions of Directive 1999/5/EC. A copy of 
the signed and dated Declaration of Conformity is available on 
request via our Oregon Scientific Customer Service.

 

 

                       

COUNTRIES RTTE APPROVAL COMPLIED

All EU countries,Switzerland CH 

 

 

 

            and Norway   N

Solar Weather Station

with Outdoor Hygrometer 

Model: BAR806HG / BAR806HGA

USER MANUAL

OVERVIEW

FRONT VIEW 

1

2

3

4

5
6

7

8

9

10

11
12

13

14
15

18

19

16

17

1.   Solar panel 
2.   

:  Remote  sensor  reception  indicator  and  outdoor 

channel selected

3.   

: Outdoor remote sensor battery low

4.  Indoor temperature (Current / Max / Min)
5.   Indoor humidity (Current / Max / Min)
6.   

: Clock signal reception indicator

7.   AM / PM
8.   

: Main unit batteries low / no battery

9.  

MODE

: Change settings / display

10.  

: Increase value of the setting; activate clock reception 

signal; toggle between outdoor channels (1-3)

11.  Outdoor temperature (Current / Max / Min)
12.  Outdoor humidity (Current / Max / Min)
13.  Weather forecast
14.  

: Time zone offset

15.  Calendar / Clock with weekday / second
16.  

: Ice alert LED indicator

17.  

LIGHT

: Activate backlight 

18. 

MEM

:  View  current,  maximum  and  minimum  indoor  / 

outdoor temperature and humidity

19. 

:  Decrease  value  of  the  setting;  deactivate  clock 

reception signal

BACK VIEW 

1

2
3
4

EU

UK

1.   Wall mount hole
2.  

RESET

: Reset unit to default settings

3.  

EU  /  UK

:  Select  the  nearest  radio  signal  (BAR806HG 

only)

4.  

°C / °F

: Select temperature unit

REMOTE SENSOR

1.  LED status indicator
2.  Wall mount hole
3.  Battery compartment

 

4.

  RESET 

hole 

5. 

CHANNEL 

switch

GETTING STARTED

SOLAR PANEL

The  solar  panel  is  an  energy  saving  feature,  which  is  an 
environmentally friendly way to provide additional power to 
the main unit and prolongs battery life. However, it cannot 
replace battery power entirely.

INSERT BATTERIES

1.  Remove the battery compartment.
2.  Insert the batteries, matching the polarities.
3.  Press

 RESET

 after each battery change.

REMOTE SENSOR

The main unit can collect data from up to 3 sensors.

To set up the sensor:

1.  Open the battery compartment.
2.   Insert the battery, matching the polarities.
3.  Select a channel. Press 

RESET

 after each battery change. 

4.  Close the battery door.
5.  Place  the  sensor  within  30  m  (98  ft)  of  the  main  unit 

using the table stand or wall mount. 

  TIP 

 

  Ideal  placements  for  the  sensor  would  be  in  any 

location on the exterior of the home at a height of not more 
than 1.5 m (5 ft) and which can shield it from direct sunlight 
or wet conditions for an accurate reading.

1.5 m (5 ft)

 NOTE  

Use alkaline batteries for longer usage and consumer 

grade lithium batteries in temperatures below freezing.

SENSOR DATA TRANSMISSION

To search for a sensor: 

Press and hold 

 + MODE

.

The sensor reception icon in the remote sensor area shows 
the status:

ICON

DESCRIPTION

Main  unit  is  searching  for 
sensor(s).

A channel has been found.

The sensor cannot be found. 

 TIP  

The transmission range may vary depending on many 

factors. You may need to experiment with various locations 
to get the best results.

CLOCK 

CLOCK RECEPTION

This product is designed to synchronize its clock automatically 
with a clock signal.

BAR806HG:

Slide 

EU / UK

 to select the signal received.

•   EU:  DCF-77  signal:  within  1500  km  (932  miles)  of 

Frankfurt, Germany.

•   UK:  MSF-60  signal:  within  1500  km  (932  miles)  of 

Anthorn, England.

BAR806HGA:

•   WWVB-60  signal:  within  3200km  (2000  miles)  of  Fort 

Collins Colorado.

To enable / disable signal reception:

Press  and  hold 

 

to  enable  or

 

 

to  disable  signal 

reception.

 NOTE  

Reception takes 2-10 minutes. If the signal is weak, 

it  can  take  up  to  24  hours  to  get  a  valid  signal.  If  signal 
reception is unsuccessful, place your unit next to a window, 
press and hold 

 

to force another signal search.

Clock signal reception indicator:

STRONG SIGNAL

WEAK / NO SIGNAL

MANUALLY SET CLOCK

To set the clock manually, disable the signal reception first.
1.  Press and hold 

MODE

.

2.  Press 

 

or

 

 

to change the settings.

3.  Press 

MODE

 to confirm.

 

The settings order is: time zone, 12/24 hr format, hour, 
minute,  year,  calendar  mode  (day  –  month  /  month  – 
day), month, day and language.

BAR806HG: 

Time  zone  offset  sets  the  clock  +/-  23  hours 

from the received clock signal time. If you have deactivated 
the clock signal reception, do not set a value for time zone.

BAR806HGA:

 Select the time zone: (P) Pacific, (E) Eastern, 

(C) Central or (M) Mountain.

 NOTE  

The language options are English (E), German (D), 

French (F), Italian (I), and Spanish (S), and Russian (R).

To select display mode:

Press 

MODE

  to  choose  between  clock  with  seconds  / 

weekday / calendar. 

WEATHER FORECAST

This  product  forecasts  the  next  12  to  24  hours  of  weather 
within a 30-50 km (19-31 mile) radius.

Sunny

Partially Cloudy

Cloudy

Rainy

Snowy

 

TEMPERATURE AND HUMIDITY

To toggle temperature unit:

Press 

°C / °F

.

To toggle between each outdoor sensor’s readings:

Press 

 repeatedly.

OR
Press  and  hold 

  + 

MEM

  for  2  seconds  to  initiate  auto 

toggle of outdoor channels.  
To end press 

.

To  toggle  between  current,  minimum  and  maximum 
records:

Press 

MEM

 repeatedly.

To clear the records:

Press and hold 

MEM

.

ICE WARNING 

If the channel 1 sensor falls between 3°C to -2 °C (37°F to 
28°F), LED indicator will flash, and will stop flashing once the 
temperature is out of this range. 

 NOTE 

 As ice alert is only applicable to channel 1, to prevent 

flashing of LED, select channel 2 or 3 on outdoor sensor.

BACKLIGHT

Press 

LIGHT

 to activate backlight for 5 seconds.

RESET

Press 

RESET

 to return to the default settings.

2

3

4
5

1

FCC STATEMENT

This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.

 WARNING 

 Changes or modifications not expressly approved 

by the party responsible for compliance could void the user’s 
authority to operate the equipment.

 NOTE 

 This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide 
reasonable  protection  against  harmful  interference  in  a 
residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency energy and, if not installed and used in accordance 
with  the  instructions,  may  cause  harmful  interference  to 
radio  communications.  However,  there  is  no  guarantee 
that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures:
• 

Reorient or relocate the receiving antenna.

• 

Increase  the  separation  between  the  equipment  and 
receiver.

• 

Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.

• 

Consult  the  dealer  or  an  experienced  radio  /  TV 
technician for help.

DECLARATION OF CONFORMITY

The  following  information  is  not  to  be  used  as  contact 
for  support  or  sales.  Please  visit  our  website  at  www2.
oregonscientific.com/service for all enquiries.

We

Name: 

Oregon Scientific, Inc.

Address: 

19861 SW 95

th

 Ave.,Tualatin,

 

Oregon 97062 USA

Telephone No.: 

1-800-853-8883

declare that the product 

Product No.: 

BAR806HG / BAR806HGA

Product Name: 

       Solar Weather Station  

 

 

       with Outdoor Hygrometer

Manufacturer: 

IDT Technology Limited

Address: 

Block C, 9/F, Kaiser Estate, 

 

Phase 1,41 Man Yue St.,     

 

Hung Hom, Kowloon, 

 

Hong Kong

is in conformity with Part 15 of the FCC Rules.  Operation is 
subject to the following two conditions: 1) This device may 
not cause harmful interference. 2) This device must accept 
any  interference  received,  including  interference  that  may 
cause undesired operation.

Station météorologique solaire à 

hygromètre extérieur

Modèle: BAR806HG / BAR806HGA

MANUEL DE L’UTILISATEUR

VUE D’ENSEMBLE

FACE AVANT

1

2

3

4

5
6

7

8

9

10

11
12

13

14
15

18

19

16

17

1.   Panneau solaire
2.   

: Icône de réception de la sonde sans fil et indique que 

le canal extérieur est sélectionné

3.   

: La pile de la sonde sans fil est faible

4.   Température intérieure (actuelle, Max/Min)
5.   Humidité intérieure (actuelle, Max/Min) 
6.   

: Indicateur de réception du signal de l’horloge

7.   AM / PM
8.   

: Les piles de l’appareil principal sont faibles / aucune 

pile

9.  

MODE

: Modifie les réglages / l’affichage

10. 

:  Augmente  la  valeur  d’un  réglage;  active  le  signal 

de  reception  de  l’horloge;  permet  d’alterner  entre  les 
canaux (1-3)

11.  Température extérieure (actuelle, Max/Min)
12.  Humidité extérieure (actuelle, Max/Min) 
13.  Prévision météorologique
14.  

: Fuseau horaire

15.  Calendrier  /  horloge  avec  affichage  des  jours  de  la 

semaine / secondes

16.   : Indicateur LED d’alerte de gel
17.  

LIGHT

: Permet d’activer le rétro-éclairage

18. 

MEM

:  Affichage  des  temperatures  et    humidités 

intérieures / extérieures actuelle/maximum/minimum

19. 

:  Diminue  les  réglages;  désactive  le  signal  de 

reception de l’horloge

FACE ARRIÈRE 

1

2
3
4

EU

UK

1.    Trou de fixation murale
2.  

REINITIALISER  (RESET)

:  Réinitialiser  l’appareil  aux 

réglages par défaut

3.  

EU  /  UK

:

 

Sélectionne  le  signal  radio  le  plus  proche 

(modèle BAR806HG uniquement)

4. 

°C / °F

: Sélectionne l’unité de mesure de température

EN

FR

SONDE SANS FIL

1.   Indicateur d’état LED
2.   Trou de fixation murale
3.   Compartiment des piles
4.   Fente 

REINITIALISER

 (

reset

)

5.   Bouton 

CANAL (channel)

POUR COMMENCER

PANNEAU SOLAIRE 

Le panneau solaire est un accessoire permettant d’économiser 
l’énergie, c’est une façon écologique de fournir de l’électricité 
supplémentaire à l’appareil principal prolongeant la durée de 
vie  de  la  pile.  Il  ne  peut  cependant  remplacer  entièrement 
l’alimentation par piles.

INSÉREZ LES PILES

1.   Retirez le couvercle du compartiment des piles. 
2.   Insérez les piles en respectant les polarités.
3.   Appuyez  sur

  REINITIALISER  (RESET) 

après  chaque 

changement de piles.

SONDE SANS FIL

L’appareil principal est à même de collecter les données de 
3 sondes maximum.

Pour installer le capteur:

1.   Ouvrez le couvercle du compartiment des piles.
2.    Insérez la pile, en respectant les polarités.
3.   Sélectionnez  un  canal.  Appuyez  sur 

RESET

  après 

chaque changement de piles.

4.   Fermez le couvercle du compartiment des piles.
5.   Installez  le  capteur  à  30  m  maximum  (98  pieds)  de 

l’appareil principal à l’aide du support de table ou de la 
fixation murale.

 CONSEIL  

Les emplacements idéaux pour le capteur sont 

dans  tout  endroit  extérieur  à  l’habitat,  à  une  hauteur  ne 
dépassant pas les 1.5m (5 pieds) et permettant de le protéger 
contre la lumière directe du soleil ou des conditions humides, 
afin d’obtenir une lecture précise. 

1.5m

  REMARQUE   

Utilisez  des  piles  alcalines  pour  un  usage 

prolongé et des piles au lithium pour la consommation lors 
de basses températures (gel).

TRANSMISSION DES DONNEES DU CAPTEUR

Pour rechercher un capteur:

Appuyez et maintenez la touche 

 

+ MODE.

L’icône  de  réception  du  capteur  située  dans  la  zone  de  la 
sonde à distance, indique l’état :

ICONE

DESCRIPTION

L’appareil principal est 
à la recherche du/des 
capteur(s).

Un canal a été trouvé.

Le capteur est introuvable.

 CONSEIL  

La portée de transmission peut varier en fonction 

de  plusieurs  facteurs.  Vous  pouvez  essayer  plusieurs 
emplacements,  afin  d’obtenir  les  meilleurs  résultats 
possibles.

 

HORLOGE 

RÉCEPTION DE L’HORLOGE

Ce  produit  est  conçu  pour  synchroniser  automatiquement 
l’horloge avec le signal radio.

BAR806HG:

Positionnez  l’encoche 

EU  /  UK

  pour  sélectionner  le  signal 

à recevoir.
•   EU:  Signal  DCF-77:  dans  un  rayon  de  1500  Km  (932 

miles) depuis Frankfort, Allemagne.

•   UK:  Signal  MSF-60:  dans  un  rayon  de  1500  Km  (932 

miles) depuis Anthorn, Angleterre.

BAR806HGA:

•   Signal  WWVB-60:  dans  un  rayon  de  3200  km  (2000 

miles) de Fort Collins, Colorado.

Pour activer / désactiver le signal de réception:

Appuyez et maintenez   pour activer ou   pour désactiver 
la réception du signal.

 REMARQUE 

 La réception prend entre 2 et 10 minutes. Si 

le signal est faible, 24 heures peuvent être nécessaires pour 
obtenir un signal valide. Si la réception échoue, positionnez 
votre appareil à proximité d’une fenêtre, appuyez et maintenez 

  pour forcer la recherche de signal. 

Indicateur de réception du signal de l’Horloge:

SIGNAL FORT

SIGNAL FAIBLE / AUCUN 

SIGNAL

RÉGLER MANUELLEMENT L’HORLOGE

Pour régler manuellement l’horloge, vous devez, tout d’abord, 
désactiver la réception du signal.

1.   Appuyez et maintenez la touche 

MODE

.

2.   Appuyez sur 

 ou 

 pour modifier les réglages.

3.   Appuyez sur 

MODE 

pour confirmer.

 

Les réglages s’effectuent dans l’ordre suivant :  fuseau 
horaire,  format  12/24  heures,  heure,  minute,  année, 
mode calendrier mois/jour, jour/mois, mois et langue.

BAR806HG: 

La fonction fuseau horaire règle l’horloge à +/- 23 

heures de l’heure du signal reçu. Si vous avez désactivé la 
réception du signal de l’horloge, ne configurez pas de valeur 
pour le fuseau horaire.

BAR806HGA:

  Sélectionnez  le  fuseau  horaire:  Heure 

Pacifique  (P),  des  Montagnes  (M),  Centrale  (C)  ou  de  la 
Côte Est (E).

  REMARQUE   

Les  langues  disponibles  sont  l’anglais  (E), 

l’allemand (D), le français (F), l’italien (I), l’espagnol (S), et le 
russe (R).

Pour sélectionner le mode d’affichage:

Appuyez sur

 MODE 

pour choisir l’affichage de l’horloge avec 

les secondes / jours de la semaine / calendrier.

PRÉVISION MÉTÉO

Ce  produit  vous  permet  de  savoir  les  prévisions 
météorologiques pour les 12 à 24 heures dans un rayon de 
30 à 50 Km (19-31 miles).

Ensoleillé

Partiellement nuageux

Nuageux

Pluvieux

Neige

TEMPÉRATURE ET HUMIDITÉ

Pour sélectionner l’unité de température:

Appuyez sur 

°C / °F

.

Pour alterner entre les relevés de chaque sonde sans fil:

Appuyez plusieurs fois sur 
OU
Appuyez et maintenez 

 + 

MEM

 pendant 2 secondes pour 

lancer l’alternance automatique des canaux extérieurs. 

2

3

4
5

1

BAR806HGA_US_M_R3.indd   1

2009.4.17   5:29:02 PM

www.OregonScientificStore.com

Reviews: