background image

6

EN

CLOCK 

CLOCK RECEPTION

 RECEPTION SIGNAL 

To enable and force a signal search:

Press and hold   for 2 seconds.

To disable the signal reception:

Press and hold   for 2 seconds.

 STRONG SIGNAL    WEAK SIGNAL     NO SIGNAL

 SET CLOCK

If the clock signal reception is enabled and a signal is 
being received the clock does not need to be manually 
set. 

1.  Press and hold 

MODE

 for 2 seconds.

2.   Press   or   to change the settings.
3.   Press 

MODE

 to confirm.

4.   The settings order is: time zone offset, hour, minute, 

year, month, day and language. 

NOTE 

The time zone offset can be used to set the clock 

up to + / - 9 hours from the received clock signal time. 

If  you  have  disabled  the  clock  signal  reception  (i.e. 

manually setting the clock), do not set a value for time 

zone offset.

NOTE

 The language options are English  (E), German 

(D), French (F), Italian (I), and Spanish (S).

Press 

MODE

 to choose between the clock with seconds 

and clock with weekday display modes.

Clock signal reception indicator:

To search for a sensor: 

Simultaneously,  press  and  hold 

MEM

  and 

CHANNEL

 

for 2 seconds.

NOTE

 If the sensor is still not found, check the batteries, 

obstructions, and remote unit location.

This  product  is  designed  to  synchronize  its  date  and 
time automatically once it is within range of:

   DCF-77  generated  from  Frankfurt,  Germany  for 

Central Europe.

   MSF-60 generated from Rugby, England.

The clock collects the radio signals whenever it is within 
1500 km (932 miles) of a signal.

NOTE

 Slide the 

EU 

UK

 switch to appropriate position for 

your location. Repeat each time you reset the unit.

NOTE

 Initial reception takes 2-10 minutes for first set 

up  or  when

  RESET

  is  pressed.  Once  complete,  the 

reception icon will stop blinking. If the signal is weak, it 
can take up to 24 hours to get a valid signal.

Summary of Contents for BAR388HG

Page 1: ...ting Started 4 Batteries 4 Remote Sensor 4 Sensor Data Transmission 5 Clock 6 Clock Reception 6 Reception Signal 6 Set Clock 6 Alarm 6 Barometer 7 Set Altitude 7 Weather Forecast 7 Temperature and Hum...

Page 2: ...you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know about CLOCK OVERVIEW FRONT VIEW 1 SNOOZE 2 Weather Forecast Ar...

Page 3: ...unit to default settings 11 Battery compartment 1 Pressure trend 2 Weather forecast 3 Comfort zone 4 Pressure icon 5 Altitude icon 6 Pressure altitude unit 7 Heat index 1 Heat index icon 2 Hi lo temp...

Page 4: ...t use matching the polarity and Press RESET after each battery change indicates main unit batteries are low NOTE Do not use rechargeable batteries We recommend that you use alkaline batteries with thi...

Page 5: ...it will resume proper functioning as the temperature rises to within the normal temperature range i e no permanent damage will occur to the unit due to low temperatures 3 Select a channel Make sure yo...

Page 6: ...s are English E German D French F Italian I and Spanish S Press MODE to choose between the clock with seconds and clock with weekday display modes Clock signal reception indicator To search for a sens...

Page 7: ...again after 24 hours To ensure barometric readings are reliable set the altitude to reflect distance from sea level at your position 1 Press and hold PRESSURE for 2 seconds 2 Use and to set the altitu...

Page 8: ...bility of heat dehydration 32 2 40 C 90 104 F Caution Possibility of heat exhaustion 26 6 31 7 C 80 89 F To end auto scan Press CHANNEL or MEM To toggle between current minimum and maximum records for...

Page 9: ...RESET to return the unit to the default settings When calendar is set press or to view the moon phase for the next previous day Press and hold or to scan through the years 2001 to 2099 PRECAUTIONS Th...

Page 10: ...MM language selectable E D F I and S 3 x UM 3 AA 1 5 V batteries 92 x 60 x 20 mm 3 6 x 2 4 x 0 8 in 62 g 2 22 oz 30 m 100 ft unobstructed REMOTE UNIT Temperature range Power 30 C to 60 C 22 F to 140...

Page 11: ...u re in the US and would like to contact the Oregon Scientific Customer Care department directly please visit www2 oregonscientific com service default asp OR Call 1 800 853 8883 For international inq...

Reviews: