background image

11

GB

The radio reception signal [ ] and the outline of the US-Map icon
will start blinking to initiate reception automatically.

HOW TO SET THE CLOCK MANUALLY

To set the clock manually, hold [MODE/SET] for three seconds. The
hour digits will blink.

Hold and keep the respective button pressed to rapidly increase or
decrease the value of the hour digits.

Press [MODE/SET] to confirm. The minute digits will blink.

Repeat the same procedure to set the minutes, year, month, day and
display language.

Note: The time and date are displayed in 12-HOUR clock format.
For the language display, you can choose among English (E),  French
(F) and Spanish (s).

For the US time zone, select the time-zone by using the [ZONE]
button to toggle Pacific, Mountain, Eastern or Central.

If there is a setting you do not wish to change, simply press [MODE/
SET]
 to bypass the setting.

When you are done, press [MODE/SET] to exit. The display will
return to the mode last chosen.

HOW TO SET AND ARM THE ALARMS

The BAR122HGA has a daily alarm function.

To set an alarm:

1.

Press 

  ]

 once to enter the Alarm display mode.

2. Press and hold 

 ] for three seconds. The hour digits

will blink.

3. Enter the hour using [ TIME / 

 ] or [ TIME / 

 ] buttons.

4. Press 

 ]. The minute digits will blink.

5. Enter the minutes using [ TIME / 

 ] or [ TIME / 

 ] buttons.

6. Press 

 ] to exit. The 

 ] icon for the alarm chosen

will be displayed indicating the alarm set above is now armed.

You can also arm or disarm an alarm by pressing the
[ AL ] button.

When an alarm is armed, it will go off at the set time.

The four-step crescendo function allows the alarm to start off gently
and step up its intensity every 20 seconds for four times. Without
interruption, the alarm will sound for a total of two minutes. If no
key is pressed to turn off the alarm within these 2 minutes, the alarm
will sound once more after 8 minutes.

- Strong

- Weak

- No signal

- Receiving

b122hga-e.p65

08/10/2001, 12:17 PM

11

Summary of Contents for BAR122HGLA

Page 1: ...at helpme oscientific com WARRANTY This product is warranted to be free of manufacturing defects for a period of 1 year from date of retail purchase Defective product should be directed to the place o...

Page 2: ...to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor...

Page 3: ...corrosive materials Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit 3 Do not subject the unit to excessive force shock dust temperature or humidity Such treat...

Page 4: ...tting When you are done press MODE SET to exit The display will return to the mode last chosen HOW TO SET AND ARM THE ALARMS The BAR122HGA has a daily alarm function To set an alarm 1 Press once to en...

Page 5: ...N The BAR122HGA is designed to automatically synchronize its calendar clock when it is within range of the radio signal from the U S Atomic clock When the BAR122HGA is new and initially set up recepti...

Page 6: ...the steps to set the upper temperature and humidity setting and the lower temperature and humidity settings 4 When finished press HI LO to set another limit or wait 16 seconds and the unit will automa...

Page 7: ...ay the maximum temperature and humidity and press MEMORY again to display minimum temperature and humidity The respective indicators MAX or MIN will be displayed To clear the memory Press and hold MEM...

Page 8: ...CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Press either CHANNEL MEMORY HI LO U U U U U ON OFF TEMP RH AL COMFORT LEVEL INDICATORS The comfort level indicators COM WET or DRY...

Page 9: ...e kinetic wave DISCONNECTED SIGNALS If without obvious reasons the display for a particular channel goes blank press CHANNEL MEMORY to enforce an immediate search If that fails check 1 The remote unit...

Page 10: ...d when the unit is operating in an unfavorable way or malfunctioning To return all user programmed settings to their original factory values press RESET by using a blunt stylus to hold down the button...

Page 11: ...teries 3 Replace the battery compartment door BATTERY AND CHANNEL INSTALLATION REMOTEUNIT The remote thermo hygro sensor unit uses two 2 UM 3 or AA size batteries Follow these steps to install replace...

Page 12: ...ettings to original factory set values F BATTERY COMPARTMENT Accommodates two 2 UM 3 or AA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE...

Page 13: ...ME BUTTON Decrease the value of a setting K TIME BUTTON Advances the value of a setting L BUTTON Displays the alarm time or changes the alarm set time TEMPERATURE RELATIVE HUMIDITY ALARM for Channel 1...

Page 14: ...HGA This unit has a large four line liquid crystal display LCD for displaying weather forecast information in outdoor temperatures and relative humidity radio frequency RF controlled calendar clock an...

Reviews: