background image

EN

5

NOTE:

1. The accuracy of a general pressure-based weather forecast is

about 70 to 75%, and therefore, cannot be held responsible for
any inconveniences so caused by an inaccurate forecast.

2. The weather forecast is meant for the next 12 to 24 hours. It may

not necessarily reflect the current situation.

3. The “Sunny” icon, when applies to night time, implies clear

weather.

INDOOR RELATIVE HUMIDITY

The indoor relative humidity is automatically detected. The reading
is displayed in the relative humidity window.

Like temperature, the maximum and minimum relative humidity
will be stored in memory. Use the MEMORY button to rotate
through the maximum, minimum and current relative humidity. The
respective MAX and MIN indicator will be displayed.

To clear the memory, hold down MEMORY for three seconds. The
maximum and minimum temperatures will be erased. If you press
MEMORY now, the maximum and minimum relative humidity will
have the same values as the current one until different readings are
recorded.

COMFORT LEVEL

The comfort level is based on the recorded relative humidity. An
indicator will be displayed to show if the level is comfortable, wet or
dry.

ATMOSPHERIC PRESSURE

The current atmospheric pressure is shown on the atmospheric
pressure window. If you need to adjust the altitude compensation,
follow the procedure set in HOW TO SET THE
CALENDAR MANUALLY.

The atmospheric pressure can be displayed in mb/hPa or inHg. The
unit is selected on the atmospheric pressure slide switch.

If you want to know the pressure history for a particular hour during
the past 24 hours, press the HISTORY button. Each press on the
button will go back by an hour. Holding down the button will
increase the value rapidly.

The recorded atmospheric changes for the past 24 hours are displayed
in a bar chart above the atmospheric pressure window.

HOW TO USE AND SCAN

THE MOON PHASE

The BAR928 is equipped with a moon phase display and scanner
with which eight moon phases are displayed on the screen  from new
moon to waning crescent. The one falls on the current day will flash
on the screen.

If it is a full moon or new moon day, the icon will flash faster.

The eight phases are:

To check the moon phase for a particular day, press the UP or
DOWN button once. The clock will enter moon phase scanning
mode.

Use the UP or DOWN button to locate the date you want to check.
The calendar will be day-driven in this mode.

You can go back in time or travel to the future, any day between the
years 1990 to 2089. The corresponding moon phase will appear
immediately on the screen.

The unit will return to the last display mode when the UP and
DOWN buttons are left idle for 15 seconds.

HOW TO WALL MOUNT OR USE

THE TABLE STAND

The unit can be wall-mounted using its recessed screw holes or place
on a flat surface using its table and control stand. To use the stand,
lay the control panel on a flat surface. Then adjust the angle of the
display panel for best display and support.

Table stand

Wall-mount

New Moon

Waxing Crescent

First Quarter

Waxing Gibbous

Waning Crescent

Last Quarter

Waning Gibbous

Full Moon

BAR928-E R1 OP

8/21/04, 11:54 PM

5

Summary of Contents for BA928

Page 1: ...Cable Free Weather Station Model BAR928 User Manual BAR928 E Cover R1 OP 8 21 04 11 55 PM 1 Black ...

Page 2: ...MHz it can be used in the U S and most places in Continental Europe MAIN FEATURES MAIN UNIT A RADIO RECEPTION SIGNAL Indicates the condition of radio reception B SNOOZE LIGHT BUTTON Activates the snooze function when an alarm goes off or turn on the backlight for five seconds C MODE WINDOW Displays the current time and date D ALARM ON ICON Appears when the alarm is activated E ALARM ICON Appears w...

Page 3: ...it B LED INDICATOR Flashes when the remote unit transmits a reading C C F SLIDE SWITCH Selects between Centigrade C and Fahrenheit F D RESET BUTTON Returns all settings to default values E BATTERY COMPARTMENT Accommodates two UM4 or AAA size batteries F WALL MOUNT HOLDER Supports the remote unit in wall mounting G REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGI...

Page 4: ...CK MANUALLY When the current time is displayed press MODE for three seconds The 12 hr or 24 hr digits will flash Use the UP or DOWN button to select either If 12 hour clock format is selected the time will be displayed with the AM or PM indicator Press MODE The hour digits will flash Use the UP or DOWN buttons to enter the hours Holding down either button will increase or decrease the value rapidl...

Page 5: ...ORECAST The unit is capable of detecting atmospheric pressure changes and basing on the data collected can predict the weather for the forth coming 12 to 24 hours The effective range covers an area of 30 to 50 km MULTILINGUAL DAY OF THE WEEK The display language of the day of the week is selected in the calendar setting procedure The foreign languages and their mean ings are as follows HOW TO SET ...

Page 6: ...he atmospheric pressure slide switch If you want to know the pressure history for a particular hour during the past 24 hours press the HISTORY button Each press on the button will go back by an hour Holding down the button will increase the value rapidly Therecordedatmosphericchangesforthepast24hoursaredisplayed in a bar chart above the atmospheric pressure window HOW TO USE AND SCAN THE MOON PHAS...

Page 7: ...The RESET button allows you to return all settings to its factory values The button is required only when the unit is not operating in a favorable way such as in the rare case of a malfunction The RESET button is located inside the battery compartment door To use the button 1 Lift open the battery compartment door 2 Press the button with a blunt stylus 3 Replace the battery compartment door PRECAU...

Page 8: ...Oregon Scientific Customer Caredepartmentdirectly pleasevisit www2 oregonscientific com service support OR Call 949 608 2848 in the US Forinternationalenquiries pleasevisitwww2 oregonscientific com about international default asp EC DECLARATION OF CONFORMITY This product contains the approved transmitter module that complies withtheessentialrequirementsofArticle3oftheR TTE1999 5 EC Directive if us...

Page 9: ... 2004 Oregon Scientific All Rights Reserved 086 001853 226 BAR928 E Back R1 OP 8 21 04 11 55 PM 1 Black ...

Reviews: