2

fungi as a result. Moreover, it is also a fact that heating 
this humid air consumes more energy. 

It is, therefore, important to ventilate 24 hours per day.

If you have any questions, please contact your supplier. 
The contact details can be found in the installation and 
measurement report.  

2. How does the ventilation system work?

Your home is equipped with a mechanical extraction 

ventilation system from Orcon BV. This system consists 
of a centrally-located fan unit with a highly energy-

efficient EC motor, ductwork with extraction valves in 

the kitchen, bathroom, lavatory and possibly the storage 
area, all combined with a remote control and/or CO

2

 room 

sensor(s). The device can be fitted with a MOTORLESS 

cooker hood. This discharges cooking odours and humidity 
to the exterior via the central device.

It is not permitted to connect a cooker hood with 
motor or clothes dryer to the system.

Depending on the size of the home, the installer can 
set the system to deliver the correct volume of air. 

The ventilation system has four speed positions; absent, 

low, medium and high. These different setting options 

ensure that cooking odours and humidity are efficiently 

removed from the home. The MVS-15RH system was 
designed to operate 24 hours per day. The device is 

equipped with a highly energy-efficient EC motor to keep 

energy consumption to a minimum.

3. Operating the system:

For the device to function properly, the following conditions 
must be respected.

•  Ensure that sufficient air can be fed through transom 

windows or intake grilles.

•  If your home is fitted with non-closable air inlet openings, 

do not seal them or cover them with tape.

Summary of Contents for MVS-15RH

Page 1: ...s manual contains important information about the installation and configuration of the domestic ventilator The user manual can be found at the back of this manual This manual concerns the following m...

Page 2: ...vice must be performed in accordance with the general and locally applicable construction safety and installation instructions of the municipality and power company 3 When performing work on the devic...

Page 3: ...e motor plate The humidity sensor is on the receiver PCB Steps for installing the MVS 15RH 1 Mount the MVS 15RH device on a wall or ceiling with sufficient mass 200 kg m2 2 Install a silencer at least...

Page 4: ...the unit cut the adapter pyramid away with a Stanley knife Mounting RF remote control MVS 15RHB The remote control can be opened via the push button see figure 6 which is located on the underside The...

Page 5: ...2 6 168 159 28 387 28 76 208 13 Fig 4 Rear view with 160 mm connection Fig 5 Base view with 125 mm and 160 mm connection 124 124 159 124 124 87 215 463 124 303 430 Fig 2 Side view MVS 15 Fig 3 Top vie...

Page 6: ...DIP switch functions Options DIP switch 7 8 Table A curve speeds Off Table B curve speeds On 15 minute afterrun humidity sensor Off 30 minute afterrun humidity sensor On 6 Fig 7 Receiver PCB in the de...

Page 7: ...is not suitable for three phase current Supply voltage 230 V 50 Hz 4 Adjustment of air volume 1 Close the windows and doors 2 Set the extraction valves and ZR grilles to their fully open positions 3 S...

Page 8: ...ium 4a On Off Off Off 171 62 9 Medium 5a Off On Off Off 197 81 12 Medium 6a On On Off Off 222 101 15 Medium 7a Off Off On Off 245 123 20 Medium 8a On Off On Off 270 150 27 Medium 9a Off On On Off 293...

Page 9: ...6 Medium 4b On Off On 215 34 10 Medium 5b Off On On 271 53 16 Medium 6b On On On 324 77 25 High 7b Off Off Off On 298 65 29 High 8b On Off Off On 353 92 31 High 9b Off On Off On 381 107 38 High 10b On...

Page 10: ...g mode and can be linked to a remote control or CO2 room sensor The MVS 15RH always starts up in automatic mode TheMVS 15RHisalsoequippedwithahumiditysensor This isintegratedintheventilationcabinet An...

Page 11: ...n successfully paired the LED on the device and remote control will flash green 10 times and the device will briefly accelerate The remote control is now ready for use Reset remote control A remote co...

Page 12: ...on the receiver PCB flashes alternately red green red Any connections with the remote control s CO2 room sensor s are now deleted and the factory settings are loaded The LED on the receiver PCB remain...

Page 13: ...he receiver PCB with the humidity sensor on the back are located behind this cover Removing and installing motor plate After the front cover has been removed the motor plate can be lifted out with the...

Page 14: ...ally If the LED repeatedly flashes green twice the MVS 15RH is in position 2 or 3 due to increased humidity levels If the LED repeatedly flashes green three times the MVS 15RHB CO2 is in position 2 or...

Page 15: ...Normal operation no hu midity CO2 or timer signal Flashing green 2x Humidity scenario active Flashing green 3x CO2 scenario active Exter nal CO2 room sensor Flashing green 4x Timer scenario active 7...

Page 16: ...temperature 0 40 C RH level 0 90 non condensing Protection class IP30 Functional range 400 2000 ppm RF remote control Supply voltage Powered by 3 V battery Temperature class T40 Dimensions 83 x 80 x 2...

Page 17: ...uarantee period it must be reported to the installer Orcon BV reserves the right to change the structure and or configuration of its products at any time without being obliged to change previously sup...

Page 18: ...on off 2 on off 3 on off 4 on off 5 on off 6 on off 7 on off 8 on off 18 Installation report Date Address Town or City Type of project Type of property Client Installed by Measured by Type of device S...

Page 19: ...Space valve Position on device Required m3 h Measured m3 h Setting MKL valve 1 6 Kitchen Lavatory Bathroom 19...

Page 20: ...s damp and musty This attracts mould and house dust mites Poor ventilation means damp patches in walls and ceilings are a certainty as well as health problems such as headaches allergies and respirato...

Page 21: ...his discharges cooking odours and humidity to the exterior via the central device It is not permitted to connect a cooker hood with motor or clothes dryer to the system Depending on the size of the ho...

Page 22: ...windows or grilles in window frames or sliding patio doors Under no circumstances seal or tape air inlet grilles The domestic ventilator is operated by a wireless remote control in automatic mode the...

Page 23: ...cted position The timer can be cancelled by selecting another button Absence mode In the absence mode the device runs in an extra energy efficient low position and does not respond to signals from sen...

Page 24: ...n through the self regulating grilles CO2 room sensor indication and control If the control button is pressed once the LEDs show the status After 30 seconds the LEDs will automatically turn off This p...

Page 25: ...remote control This then cancels automatic mode In the event of a power interruption the fan starts in automatic mode 4 Maintenance System maintenance The home owner must ensure that the fan is checke...

Page 26: ...emove the old battery from the remote control Insert the new battery with the positive side facing you see figure 4 Replace the protective cover and click the upper side shut on the wall frame with a...

Page 27: ...itmustbereportedtotheinstaller OrconBVreserves the right to change the structure and or configuration of its products at any time without being obliged to change previously supplied products The data...