24
Error Code
Fault
Symptoms and
Trouble shooting
E1
Communication abnormal:
The controller and console
has abnormal
communication
1. Check the connecting wire between console and
controller if connection is good.
2. When wire is in good condition, change the controller to
see if problem solved.
3. When wire is in good condition, change the console to
see if problem solved.
E2
Motor doesn’t connect well.
1. Check if motor wire connects ell, and try to re-connect.
2. Check if there is un-usual smell, and change the
controller to see if problem solved.
E3
Current overload protection:
When current exceeds the
set value, system shows E3
to protect the motor, or when
a certain part of treadmill got
stuck, motor cannot run so
that the current overloads
and system’s self protection
turns on.
1. Check the condition of treadmill and re-turn on the power
of treadmill.
2. Check if motor has any sound of current overload or any
burnt smell when operating. If so, change the motor to
see if problem solved.
3. Check if there’s any burnt smell from controller. If so,
change controller.
4. Check if voltage fits the standard or under required
voltage. Try to use it under correct voltage range.
E6
Rush protection
1. Check if there is an un-usual smell. If so, change the
controller to see if problem solved.
__
Console cannot defect the
signal of safety key
1. Check if safety key is in good condition, or if wire
connects well, or the magnet is put in the correct place.
2. When above methods do not work, change safety key to
see if problem solved.
Console shows
up as “Blank”
1. Check if power cable connects well.
2. Check if power switch is on.
3. Check if fuse is burnt down.
4. Check if wire connecting well console and controller is in
good condition or connects well.
5. When above methods do not work, change console to
see if problem solved.
Error code and trouble shooting