TYPICAL CONFIGURATIONS
Fan Turn
Flip Turn
Back to Back Turns
STEP BY STEP INSTALLATION INSTRUCTIONS
Around Fixed Objects
shelf
ONLY CUT THE MESH THAT THE CABLE IS ATTACHED TO. DO NOT CUT THE HEATING CABLE!
1. Measure the area to be heated and verify that the mat you received is correct. Compare your net square
footage to the Mat information located within table 1 on page 3. Perform testing procedure located on
page 3 before beginning the installation. Caution: Handle the product with care and do not press or drop
any sharp objects into the Millimat.
2. If the subfloor is made of combustible material, a non-combustible layer must be laid prior to installing
the heating mat. The non-combustible lay must be leveled and stable.
3. Determine the thermostat location and install your double gang box as required by code. Electrical
conduit sized by code are recommended for mat cold leads and thermostat floor sensor.
4. Start on the floor close to where the thermostat is going to be. When making adjustments for placement,
do not cut the cable, only the mesh. When cutting and adjusting mat, ensure that he cables are kept at
the same distance from each other as the cables on the mat itself. The heating cable shall not touch,
cross, or overlap itself. Make sure that the splice (the connection between cold and hot part of the cable)
is placed in the floor and embedded. Note: The splice is much wider and thicker than the cable and is
easily identified. It may have to be recessed into the sub-floor to provide a level surface for the tile
installer.
5. If a floor sensor is used, it must be connected at equal distance between two cable runs. It is
recommended to install the floor sensor inside a conduit.
6. Starting on the sub-floor beneath the junction box, arrange the mat in the area to be heated per the
above configurations. Cut only the white mesh, and not the heating cable. When arranging the mat,
m
When mat is in place, it is
recommended to repeat the testing procedure.
7. Take a photo to document the mat layout and pour your mortar. Keep the photo as record of the cable
locations with the product warranty card.
ake sure the heating wire straddles the floor sensing conduit evenly.
2.