background image

FIGURE 11: Manual Watering in Either  

the A or B Program Only

(all stations cycle once, B program only)

n

  To activate stations assigned watering durations 

for the B program 

only, 

press the 

MANUAL

 key, 

followed by pressing the 

NExT

 

key two distinct 

times. This will activate only those stations with 

assigned watering durations in the B program only. 

To initiate this semi-automatic watering, press 

ENTER

.

Using Manual Operation

The manual operation mode allows you to set 

durations in any of the stations from 1 to 99 minutes.

n

  Turn the rotary dial to 

AUTO

.

n

  Press the 

MANUAL

 key.  Then press 

NExT

 three 

times.  The display will show a blinking cursor on 

station 1 along with 

- - MINs

 

[See Figure 12].

FIGURE 12: LCD Display with Manual Operation

n

  To set the number of minutes for watering duration, 

press and hold the 

+

 key to advance to desired 

number of watering minutes.  Use the 

-

 key to go in 

reverse.  Press 

eNter

 to begin watering.

n

  To skip a station, press 

NExT

 until the cursor 

is blinking over the station number you wish 

to program.  Example:  To set station 3 for five 

minutes, press the 

MANUAL

 key; then press the 

NExT

 key five times to select the manual operation 

mode and advance to watering for station 3; using 

the + or - key, set the manual watering duration to 

five minutes; then press 

ENTER

 

[See Figure 13].

FIGURE 13:  Manual Watering Station 3 for Five 

Minutes

note: 

 After the 

MANUAL

 key has been pushed, if a 

selection is not made within 60 seconds the display 

returns to the time of day.

n

  To halt or discontinue semi-automatic or manual 

watering, press the 

CLEAR

 

key once.  The timer will 

revert to your original automatic watering plan.

Using the User Selectable Rain Delay Mode

To stop automatic watering for 24, 48, or 72 hours, use 

the 

RAIN DELAy

 mode key.

n

  With the rotary dial set to 

AUTO

,

 press the 

RAIN DELAy

 key once then press 

ENTER

.  The 

timer will force a 24-hour interruption of all 

scheduled watering. After 24 hours, the timer will 

automatically return to its initial watering schedule.

n

  To increase the rain delay to 48 or 72 hours simply 

press the 

RAIN DELAy

 

key again until the desired 

delay time is displayed, then press 

ENTER

.

n

  To cancel the rain delay mode, press 

CLEAR

  

[See Figure 14].

FIGURE 14: LCD Display with Rain Delay

note:

 While in rain delay mode, the timer will display 

the remaining hours (counting down) to the end of the 

accepted delay alternating with the current time and date. 

No other key besides 

CLEAR

 is accepted while the timer 

is in the rain delay mode.

Complete System Shut Down

To shut the system down, turn the rotary dial to the 

OFF

 position. The timer remains programmed but will 

not water.

Installation of Indoor 

Mount Timer

Install the controller in 4 easy steps

1.  

Choosing a timer location

2.

  Mounting the timer

3.

  Connecting the transformer

4.

  Connecting valve wires to timer

1. Choosing a Timer Location

n

  Select a location near a standard electrical outlet. 

Avoid using an outlet controlled by an 

ON/OFF

 

switch.

n

  The timer should not be exposed to the weather or 

operate at temperatures below 14 degrees or above 

113 degrees Fahrenheit (-10 to 45 degrees Celsius). 

Avoid direct sunlight. For use under “normal 

pollution conditions.”

n

  Installation works best in a garage or protected 

area. The timer should not be mounted outdoors.

2. Mounting the Timer

n

  Screw a No. 8 screw at eye level leaving the screw 

head extended out from the wall about 1/8 inch. 

Use expanding anchors in plaster or masonry if 

necessary.

n

  Slip the keyhole slot in the back of the timer over 

the extended screw.

n

  Screw a No. 8 screw through each of the two holes at 

the bottom of the box into the wall 

[See Figure 15].

FIGURE 15: Mounting of 

an Indoor Timer 

(the two mounting 

holes are in the battery 

compartment) 

3. Connecting the Transformer

n

  With the wiring terminal shroud off, find the two 

terminal holes labeled

 24-VAC.

 Make sure the 

transformer is not plugged in. Insert one of the 

two power leads from the transformer into each 

terminal. It doesn’t matter which lead goes into 

which terminal. This power unit is intended to be 

correctly orientated in a vertical or floor mount 

position.

n

  It may be necessary to open the terminal to allow 

for wire insertion or removal. To do this, turn the 

screw with a Phillips screwdriver until wire is 

secure 

[See Figure 16]. 

n

  Plug in the transformer 

Warning:

 Do not link two or more controllers together 

with one  transformer.

n

  Slide the shroud back on.

FIGURE 16:

 

Connecting Transformer

PreCautions:

• This controller is not intended for use by young children 

or infirm persons without supervision.
• Young children should be supervised to ensure they do 

not play with the controller.

Installing Valves, Pump 

Start Relays & Master 

Valves

1. Wiring the Electric valves

n

  If the distance between the controller and valves is 

under 700 feet (210 m), use WaterMaster

®

 sprinkler 

wire or 20 gauge (AWG) plastic jacketed thermostat 

wire to connect the controller to the valves. If the 

distance is over 700 feet (210 m), use 16 gauge 

(AWG) wire. Terminals accept up to 14 gauge wire. 

The wire can be buried in the ground; however, for 

more protection wires should be pulled through 

conduit and buried underground. Be careful to avoid 

burying the wires in locations where they could be 

damaged by digging or trenching in the future.

n

  Each valve has two wires. One wire is to be 

connected as the common. The common wires for 

all the valves can be connected together to one 

common wire going to the timer. The other valve 

wire is to be  connected to the specific station wire 

that will control that valve  

[See Figure 17].

FIGURE 17: Connecting Timer Wires to valves

n

  All wires should be joined together using wire nuts, 

solder, and/or vinyl tape. For additional protection to 

waterproof connections, a WaterMaster

®

 grease cap 

can be used.

n

  To avoid electrical hazards, only one valve should be 

connected to each station.

n

  The rated output is 24 volts AC at less than 0.240 

Amps. Do not use solenoids that exceed these 

values.

2. Connecting valve Wires to the Timer

n

  Remove the terminal compartment cover.

n

  Strip 1/4” (6 mm) of the plastic insulation off the end 

of each wire.

n

  Determine which valve you want to connect to 

which station. Connect each valve wire to its station 

terminal (labeled 1-6) by inserting the bare wire 

fully into the terminal.

n

  It may be necessary to open the terminal to allow 

for wire insertion or removal. To do this, turn the 

screw with a Phillips screwdriver until wire is 

secure 

[See Figure 18]. 

n

  Connect the common wire to the terminal labeled 

COM

 

[See Figure 18].

FIGURE 18: Connecting valve Wires 

note:

 Only one wire can be installed into each terminal. 

If more than two common wires are used in your system, 

splice several together so only one wire runs into the COM 

terminal. Protect the splice connection with a wire nut.

Australian Rating Information

Transformer:

   

Output:  600 mA  24 VAC  50 Hz

   

Input: 

240 VAC  50 Hz

Controller Ouput: 

24 VAC

Other Quality Products 

and Accessories

Automatic Rain Shut-Off

The rain shut-off easily connects to the timer and 

prevents overwatering during rainy periods.

Weather Resistant Timer Box

Allows outdoor installation of most brands of indoor 

mount timers. UL

®

 listed.

Automatic valves

Durable, non-corrosive plastic construction. Automatic 

valves are available in anti-siphon or straight valves 

with safe, low voltage.

Automatic Converters

Durable non-corrosive plastic construction. Converts 

most brands of plastic or brass valves to automatic.

Grease Caps

Protects low voltage wires from corrosion or shorts.

Keyhole

Screw holes

No. 8 Screw

Wall

24V 24V

COM 1

2

3

4

5

6 PUMP

A

12

1

2

3

4

5

6

7

8

9

10

11

MANUAL

CLEAR

NEXT

ENTER 

RAIN DELAY

RADIO TIME

2

120

MANUAL ON

5

10

15

20

25

30

45

60

MANUAL OFF

WATERING

DURATION

MINUTE

WEEK 1

SET TIME 

AND/DATE  

SET

START

TIME

WATERING

DAYS

SET 

WATERING

DAYS

MASTER 

VALVE

RESET

DIAG. REVIEW

NEXT B/C

INTERVAL 

DAY

200

25

175

150

125

110

NORMAL

90

75

50

BUDGETING

%

PROGRAM

STATION DAY MONTH

YEAR

PROGRAM

+

Z O N E

Control Center

WEEK 2

A

B

C

B C

A

C

B

AUTO

OFF

M T W T F S S M T W T F S S

We

OFF

1

2 2000

6

1

200

Troubleshooting

Possible Causes of Problems

One or more stations do not turn on:

1.

  Faulty solenoid.

2.  

Wire broken or not connected.

3.

  Flow control stem screwed down, shutting valve off.

4.

  Programming is incorrect.

Stations turn on when they are not supposed to:

1.

  Water pressure is too high.

2.

  More than one start time is programmed.

One station is stuck on and will not shut off:

1.  

Faulty valve.

2.

  Particles of dirt or debris stuck in valve.

3.

  Valve diaphragm faulty.

All stations do not turn on:

1.

  Transformer defective or not connected.

2.

  Programming is incorrect.

3.

  Fuse has been blown.

Controller will not power up:

1.

  Fuse has been blown.

2.

  Transformer not plugged into an operational  

     AC outlet.

Stations continue to turn on and off when they are not 

programmed to:

1.

  More than one start time is programmed with  

      overlapping schedules.

2.

  Excessive pressure.

Fuse blows repeatedly:

1.  

Short in wiring or solenoids.

Help

Before returning this timer to the store, contact Orbit

®

 

Technical Service at: 

1-800-488-6156.

Listings

The timer is tested to UL-1951 (Indoor models) and 

is ETL

®

 listed. Appropriate international models are 

CETL

®

 and CE

®

 approved.

NOTE:

This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions: (1) 

This device may not cause harmful interference, and 

(2) This device must accept any interference received, 

including interference that may cause undesired 

operation.
Warning: Changes or modifications to this unit not 

expressly approved by the party responsible for 

compliance could void the user’s authority to operate 

the equipment.
NOTE: This equipment has been tested and found to 

comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against 

harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio 

frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful 

interference to radio communications. However, there 

is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause 

harmful interference to radio or television reception, 

which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

n

 Reorient or relocate the receiving antenna

n

 Increase the separation between the equipment and   

   receiver

n

 Connect the equipment into an outlet on a circuit 

different from that to which the receiver is connected

n

 Consult the dealer or an experienced radio/TV 

technician for help
This Class B digital apparatus complies with Canadian 

ICES-003.
Cet appareil numérique de la classe B est conforme à 

la norme NMB-003 du Canada.

Trademark Notice

WaterMaster

®

 is registered trademark of  

Orbit

®

 Irrigation Products, Inc. 

The information in this manual is primarily intended for 

the user who will establish a watering schedule and enter 

that schedule into the timer. This product is intended 

to be used as an automatic timer for activating 24-VAC 

irrigation valves, as described in this manual.

WaterMaster

®

 by Orbit

®

  

Limited Five year Warranty

Orbit

®

 Irrigation Products Inc. warrants to its 

customers that its WaterMaster

®

 products will be 

free from defects in materials and workmanship for 

a period of four years from the date of purchase. We 

will replace, free of charge, the defective part or parts 

found to be defective under normal use and service for 

a period of up to four years after purchase (proof of 

purchase required). We reserve the right to inspect the 

defective part prior to replacement. Orbit

®

 Irrigation 

Products Inc. will not be responsible for consequential 

or incidental cost or damage caused by the product 

failure. Orbit

®

 liability under this warranty is limited 

solely to the replacement or repair of defective parts. 

To exercise your warranty, return the unit to your 

dealer with a copy of the sales receipt.

Orbit

®

 Irrigation Products Inc.

North Salt Lake, Utah 84054
57114-14 Rev H

CUSTOMER SERVICE

1-800-488-6156

www.orbitonline.com

Valves

Specific 

Zone Wire

Wire 

Connectors

in Grease Caps

Solenoids

Common 

Wires

Jacket

24V 24V

1

2

3

4

5

6

To Station Valve

p 801 295 9820 

f 801 951 5815

www.fluid-studio.net

1065 South 500 West 

Bountiful, Utah 84010

proof no: 

1

date: 

07.09.09

des: 

SM 

spck: 

SH

job no: 

57114-14 rH

client: 

ORB

sku: 

57114

upc: 

NA

file name: 

57114-14 rH.indd

software: 

InDesign CS3

colors 

additional instructions:

· 

Font sizes cannot be smaller than 7 pt.

 

·   

· 

fold color 

non printing 

PMS 

????

PMS 
????

 

color 

non printing  

PMS 
????

 

Registration

K

 

Printers are responsible for 
meeting print production 
requirements. Any changes 
must be approved by the 
client and Fluid Studio. 
printed piece must meet 
designated specifications 
on this form
.

dimensions:
flat:  w: 
10" h: 20"
finished:  w 3.339" d: 0" 6.67"

© 2007 Fluid Studio. This 
work is the property of Fluid 
Studio, and cannot be used, 
reproduced or distributed 
in any way without their 
express permission.

All manuals and user guides at all-guides.com

Reviews: