8
SMART CHARGING STATION INSTALLATION
•
The minimum installation height for sockets and connectors
shall be 0.6 m above ground level. If the charging station is
designed for public use, the maximum height shall be 1.2 m, or
between 0.7 m and 1.2 m in places intended for persons with
reduced mobility (consult the particular instructions for the
country where the equipment is being installed in case other
heights are specified).
•
The station must be installed vertically and kept clear of
obstructions to allow for maintenance.
•
Use joints or stuffing boxes to ensure the station's IP rating.
•
The station should be installed by two people.
Assembly with stand
900
Ø63
stainless steel M16
threaded rods
corrugated tube
B30 concrete density:
350 kg of cement / m
3
55 ÷
60
250
corrugated tube
shank fastening
template