IDENTIFICATION OF TIME INTERVALS 

 
The 

MER 2T/2TN

 permits the display of the time intervals. Depending 

on the season, whether summer or winter, different values will be 
displayed.  

Accessing the identification mode 

The identification mode is accessed by pressing the “INFO” button for 
more than five seconds.  
 

Warning.

 If the button is not pressed long enough then the following 

data in the display sequence will be shown in standby or normal 
operation mode. A simple way to access the identification mode is to 
maintain the “INFO” button pressed for more than five seconds; when it 
is released, the identification display is shown. 
Once the identification mode is accessed, the following time interval will 
be displayed every three seconds.  
 

Warning.

 If the “INFO” button is pressed again, the unit will return to 

the standby or normal operation mode. 
 

Displaying the time intervals. First winter interval 

The screen displays the beginning of the time interval and the tariff 
applied as from this time. Assuming we are in winter, then we will have 
the following: 
 
 
 
 
 
 
 

Displaying the time intervals. Second winter interval. 

The screen displays the beginning of the time interval and the tariff 
applied as from this time. Assuming we are in winter, then we will have 
the following: 
 
 
 
 
 
 
 

Displaying the time intervals. Third winter interval. 

The screen displays the beginning of the time interval and the tariff 
applied as from this time. Assuming we are in winter, then we will have 
the following: 
 
 
 
 
 

 
Displaying the time intervals. First summer interval. 

The screen displays the beginning of the time interval and the tariff 
applied as from this time. Assuming we are in summer, then we will 
have the following: 
 
 
 
 
 
 
 

Displaying the time intervals. Second summer interval. 

The screen displays the beginning of the time interval and the tariff 
applied as from this time. Assuming we are in summer, then we will 
have the following:  
 
 
 
 
 
 
 

Displaying the time intervals. Third summer interval. 

The screen displays the beginning of the time interval and the tariff 
applied as from this time. Assuming we are in summer, then we will 
have the following: 
 
 
 
 
 

PROGRAMMING THE TIME INTERVALS 

 
The 

MER 2T/2TN

 permits time interval programming using the “INFO” 

and “CLOSE” buttons. Programming is protected by sealing the 
"CLOSE" button. 

Accessing the time interval programming mode 

The date and time programming mode is accessed by maintain the 
“CLOSE” button pressed for more than ten seconds.  
 

Warning.

 If this is not carefully followed, it is possible to perform an 

undesired period close operation if the “CLOSE” is not continually 
pressed for at least ten seconds. 
 
Correct access to the programming mode is indicated by the clock 
symbol appearing then disappearing on the display. 
 
Release the “PROG” key and carry out hour: minute programming 
(code 01) and hour: minute programming (code 02). 
 
Two values of hour: minute (code 01) and hour: minute (code 02) are 
programmed in order to form the following tariff structure. 
 
In winter: 
00:00 

 (code 

01) 

  

Applies period 2  (T2) 

(code 01)  

(code 02)  

 

Applies period 1  (T1) 

(code 

02) 

 00:00 

  

Applies period 2  (T2)

 

 
In summer: 
00:00 

 

(code 01) + 01:00   

Applies period 2  (T2) 

(code 01) + 01:00  (code 02) + 01:00   

Applies period 1  (T1) 

(code 02) + 01:00  00:00  

 

 

Applies period 2  (T2) 

 
The data to be programmed flashes every half second and allows the 
“INFO” button to be pressed to increase the value, while the “CLOSE” 
button will accept the new value and access the next one. The data are 
modified in tens-units sequence, in other words the tens are changed 
first, followed “CLOSE” to validate it and then the units. 
 
 

REPLACING THE BATTERY 

The MER 2T/2TN is fitted with a lithium battery to maintain the data in 
the case of a mains failure. The battery can be replaced without having 
to remove the meter. The seal on the transparent cover has to be 
broken to replace the battery. Such seals can only be broken by 
authorised personnel. 
Remove the battery-holder from its housing and take the battery out. Do 
not handle anything inside the unit. Replace the battery checking for 
correct polarity then replace the battery-holder inside its housing. Close 
the transparent cover. 
 

CHANGING SUMMER-WINTER TIME 

The summer-winter time changeover is automatically carried out on the 
official dates. 
 

CONNECTION 

Connect the equipment in accordance with the wiring diagram. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The terminals accept wires up to 7.5 mm diameter (from 6 to 25 mm

2

 

cross section). 

 

MINUTES

HOUR

INCOMING TARIFF

MINUTES

HOUR

INCOMING TARIFF

MINUTES

HOUR

INCOMING TARIFF

MINUTES

HOUR

INCOMING TARIFF

MINUTES

HOUR

INCOMING TARIFF

MINUTES

HOUR

INCOMING TARIFF

21

6

4

3

1

L
N

20

When connecting, it is essential to
secure the wire with both screws

Reviews: