background image

The sensor head can tilt about one of its axes if it is desired to displace the detection 
area. 
 
 
 
 
 
 
 
 
 
 
 
 

DETECTION INDICATORS  

There is a red LED inside the sensors that lights when a detection is made.  This 
LED can be used to assist in the adjustment of the detection field without needing to 
connect the load.  
  

SETTING THE BRIGHTNESS (only in master sensor)  

The DI circuit, as well as circuit 1 of the DICROMAT 2+, can be 
graduated to react only when the light conditions are below the level selected. By 
rotating the brightness selector to the position “

” they will react under any condition 

of brightness. By rotating the brightness selector to the position “

e

 

they only react in 

low brightness conditions. Circuit 2 (T1-T2) of the DICROMAT 2+ always reacts 
independently of the regulated brightness. 

 

 

For the changes made to take effect in the potentiometers in the adjustment of 
the equipment, it is necessary to get out from the detection area and wait for 
the installation to be turned off. 

 

SETTING THE DISCONNECTION DELAY (only in master sensor)  

By rotating the "Time 1" and "Time 2" selectors, the disconnection delay of the 
circuits is adjusted.  

 
TECHNICAL CHARACTERISTICS  

Power supply:  

230 V~  50 Hz 

Breaking power: 

μ

 10 A 230 V~  Cos 

φ

 = 1 

Recommended peak loads:  

Incandescent lamps 

2200 W 

Fluorescent tubes 

400 VA 

Low voltage halogens (12V) 

2000 VA 

Halogens (230V) 

2200 W 

Low consumption lamps (CFL) 

400 VA   

Low consumption lamps (Downligts) 

400 VA 

LED lamps 

400 VA 

 
Own consumption:  

DI: 7 VA capacitive (1.1 W approx.) 

 

DICROMAT 2+: 4.2 VA capacitive (3.1 W 

 approx.) 
Brightness range:  

2 – 2000   LUX 

Timing range:  

DI (L 

 ): From 1 s to 10 min. 

  

DICROMAT 2+: 

 

 -TIME circuit 1 (L 

 ): From 1 s to 10 min. 

 

 -TIME circuit 2 (T1-T2): From 10 s to 15 min. 

Detection angle:  

360° 

Detection field:  

Up to 7 m in diameter at 2.5 m high  

Operating temperature:  

-10° C to +45° C 

Type of protection:  

IP20 as per EN 60529  

Protection class:  

II in correct assembly conditions  

 

 