INSTALLATION, OPERATION AND MAINTENANCE MANUAL
OPERATION
Initial Operation:
Initial Operation:
Initial Operation:
Initial Operation:
Before cycling the channel gate, make sure there are no foreign deposits or materials on the seals,
guides or sealing area. Gate seals could be damaged if the area is not cleaned and coated with a
light grease. Please refer to section “Materials needed for maintenance and seal replacement” on
page 14 for detailed information about required the grease type.
•
Manual Operation:
Manual Operation:
Manual Operation:
Manual Operation:
•
Apply a light grease on the stem before initial operation after the installation. If the op-
eration is difficult due to high torque, stop operation of the gate and check stem align-
ment.
•
Electric Motor:
Electric Motor:
Electric Motor:
Electric Motor:
•
Refer to the Electric Motor Instruction Manual section before cycling the slide gate.
Manually open the gate approximately 5” before the initial electric motor operation.
Check the motor rotation to assure proper direction of the slide travel according to the
motor operation switch (open/close).
•
Special attention should be taken when the gate is almost fully open or fully closed. If the
gate does not stop once the fully open or fully closed position is reached, stop immedi-
ately and adjust the limit and torque switches (Refer to motor manual).
Operation:
Operation:
Operation:
Operation:
•
CAUTION! Do not force the operator to close the gate, as it may cause damage to the stem and
CAUTION! Do not force the operator to close the gate, as it may cause damage to the stem and
CAUTION! Do not force the operator to close the gate, as it may cause damage to the stem and
CAUTION! Do not force the operator to close the gate, as it may cause damage to the stem and
it does not improve the sealing system.
it does not improve the sealing system.
it does not improve the sealing system.
it does not improve the sealing system.
•
The CC Channel Gate is closed by a clockwise rotation, and opened by a counter-clockwise ro-
tation of the operator.
•
The CC Channel Gate’s frame incorporates a slide stopping device to stop the slide when it
reaches the fully opened position.
•
The CC Channel Gate is designed to be self-locking, so that the slide maintains its position in
open, close or intermediate positions.