PHF 50
14
•
Keep the mains cord at a safe distance from the air inlet
and outlet grilles.
•
The heating appliance must be installed at least 1.8m
above the ground. Please never install the appliance on
the ceiling
ASSEMBLY OF THE APPLIANCE
NECESSARY TOOLS:
Pencil, hammer, level, screwdriver, power drill and drill bits
A wall support is provided with the heater which has been specifically designed to allow this product to be
placed on a wall or ceiling. Before drill the holes on wall or ceiling ensure it is solid and there aren’t water
pipes or electric wires. Heater must be installed 40cm from side walls and ceiling. Mark with pencil where
you desire to place heater. Before drill the holes, check if they are level. Make holes with power drill and
place long screws with fixing studs inside holes. Place wall support on screws and fit them with nuts. Places
the other wall support on appliance and fit them with short screws. Face both supports and fit them with
screws and nuts, set the desire angle of tilt.
Important
: Ensure that once heater is mounted, power cord doesn’t contact with housing or grill of heater
when it is working, cord can be melted or burned. To avoid it you can fix power cord to wall support with
plastic flanges.