background image

HCE 74 

 

 

 

14 

 

TURNING OFF THE HEATER 

To switch the heater off: 

-

 

Place the power controller to the position 1. 

-

 

Close the gas tap. 

-

 

ATTENTION: 

The gas flow will not be stopped unless you close the valve of the gas bottle. 

NOTE: never move or cover the heater before it is completely cold. 

 

MAINTENANCE 

-

 

If any anomaly is observed or spare parts are required, contact our Technical Service. 

-

 

The periodical maintenance must be carried out by exclusively by an authorized technician. 

-

 

We  would  recommend  that  you  have  a  service  carried  out  every  two  years  by  an  authorized 
technician.  

-

 

Watch the pilot light, which should be stable. 

-

 

Check to see if it is necessary to change the flexible gas tube. If it proves necessary, obtain a new 
tube and connect it as explained in Apparatus start-up. 

-

 

It is recommended that the cleaning of the apparatus be carried out with the gas tap closed, the 
heater completely cold and with nonabrasive products. 

-

 

We  recommend,  when  the  heater  is  not  in  use,  maintaining  it  in  a  dust  free  atmosphere, 
protected with a cloth or plastic cover in a dry place. 

 

BEFORE CALLING IN TECHNICAL SERVICE 

 

 

Check to see if there is gas in the bottle and that the regulator is correctly coupled in the 
open position. 

 

Check to see that the tube is connected. 

 

Check that the instructions have been followed correctly. 

 

If this occurs after changing bottles it may be due to: 

 

There is air in the bottle. Press the ignition button down for a longer period of time until the 
pilot flame and burner ignite. Then switch to the maximum position. 

 

The bottle may have been exposed to low exterior temperatures. Apply fairly hot wet cloths 
to the upper part of the bottle to increase gasification and the normal exit of gas. 

The heater goes out 

 

If  it  goes  out  on  completing  the  ignition  instructions,  repeat  the  operation,  following  the 
instructions faithfully. 

 

If it goes after 30 minutes, it is signaling that it is operating in a stuffy atmosphere. Ventilate 
the room and reignite the heater.  

 

If it goes out before 30 minutes of operation, ensure that it is not exposed to air currents or 
that the bottle has not run out of gas. 

Summary of Contents for HCE 74

Page 1: ...ma seguridad de uso Read this manual carefully before running this appliance and save it for reference in order to obtain the best results and ensure safe use le pour toute consultation future Leia es...

Page 2: ...Control panel 3 Aeration holes 4 Protection grid 5 Ceramic panels burners 6 Pilot flame 7 Wheels 8 Structure 1 Panneau arri re 2 Tableau de contr le 3 Trous d a ration 4 Grille de protection 5 Panneau...

Page 3: ...te producto G30 Butano Aseg rese de utilizar la estufa sobre una superficie plana Preste especial atenci n cuando use la estufa en presencia de ni os ancianos minusv lidos o animales Mantenga siempre...

Page 4: ...bla en exceso de forma que evite el tr nsito de gas Cierre el paso del gas siempre que no utilice la estufa Respete cuidadosamente las condiciones de instalaci n y si percibe olor a gas o Cierre el pa...

Page 5: ...local El local donde funcione el aparato debe disponer de una entrada suficiente de aire de al menos 105 cm2 de secci n tanto en la parte superior como en la inferior Tener un volumen m nimo de 84 m3...

Page 6: ...entile el local convenientemente y espere unos minutos a volver a poner en marcha el aparato B SQUEDA DE FUGAS DE GAS El proceso de b squeda de fugas de gas debe realizarse en un lugar abierto y bien...

Page 7: ...ODS detecta falta de ox geno apagar la estufa Si esto ocurre cierre la v lvula del gas ventile la habitaci n y repita el proceso INSTRUCCIONES DE APAGADO Para apagar la estufa Gire el controlador de...

Page 8: ...s Si se produce despu s de un cambio de botella puede ser por Existir aire en la botella Alargue el tiempo de pulsado para el encendido de la chispa hasta lograr encender el piloto y el quemador Pase...

Page 9: ...control de temperatura interior A potencia calor fica nm nima elmin 0 kW dos o m s niveles manuales sin control de temperatura interior En modo de espera elSB 0 kW con control de temperatura interior...

Page 10: ...heater In case of malfunction contact a specialized technical support centre Never insert objects inside the protection grid Do not use the heater for drying clothes fabrics or other materials in par...

Page 11: ...ms Should the problem continue please contact one of our technical support centers Do not move the heater while working Never run the vacuum cleaner over the catalytic panel blow on it or wet it with...

Page 12: ...ater and to the regulator ensuring a gastight fit with the collar clips well screwed down Avoid twisting the hose Place the gas bottle on the base and fit the regulator to the bottle On opening the re...

Page 13: ...2 Position 1 is used to turn on the heater and it is also the minimum level The switch on mechanism is piezo operated A 1 Open the gas valve 2 Press the power controller and turn it to Position 1 Ign...

Page 14: ...s not in use maintaining it in a dust free atmosphere protected with a cloth or plastic cover in a dry place BEFORE CALLING IN TECHNICAL SERVICE Check to see if there is gas in the bottle and that the...

Page 15: ...room temperature control At minimum heat output elmin 0 kW two or more manual stages no room temperature control In standby mode elSB 0 kW with mechanic thermostat room temperature control with electr...

Page 16: ...une surface plane Portez une attention particuli re lors de l utilisation du po le en pr sence d enfants personnes g es handicap es ou les animaux Toujours garder une distance raisonnable de la po le...

Page 17: ...ducteur de gaz Respectez soigneusement les conditions d utilisation et si vous sentez l odeur de gaz o Fermez le r ducteur de gaz o Ouvrez les fen tres o N allumez aucun interrupteur lectrique et tei...

Page 18: ...te consultation nous indiquons ci dessoules recommandations les plus importantes Condition du local Le site de travail le dispositif doit fournir un air d entr e suffisante d au moins 105 cm2 section...

Page 19: ...on se mette en marche dans de petits locaux Si la veilleuse s teint ventilez le local convenablement et attendez quelques minutes pour remettre en marche le calorif re RECHERCHE DE FUITE DE GAZ Avant...

Page 20: ...mande de puissance Une fois que la flamme est allum e maintenir enfonc e quelques secondes Puis rel chez le 5 Si vous voulez augmenter la puissance appuyez l g rement et tournez dans le sens antihorai...

Page 21: ...ns la bouteille et si le r ducteur est correctement allum et se trouve sur la position ouverte V rifiez si le tube flexible est raccord V rifiez si les instructions ont t correctement suivies Si cela...

Page 22: ...ature de la pi ce la puissance thermique minimale elmin 0 kW contr le deux ou plusieurs paliers manuels pas de contr le de la temp rature de la pi ce En mode veille elSB 0 kW contr le de la temp ratur...

Page 23: ...no Certifique se de que o aquecedor colocado sobre uma superf cie plana Preste aten o especial ao usar o aquecedor na presen a de crian as anci os deficientes ou animais Mantenha sempre uma dist ncia...

Page 24: ...rto do aparelho Nunca deixar sem supervis o ou deix los jogar perto do aparelho Tenha cuidado de modo a evitar torcer as mangueiras de g s Feche o redutor do g s sempre que o calor fero n o esteja em...

Page 25: ...para o uso do dispositivo PRECAUC O Para a seguranca dos seus filhos nao deixe partes da embalagem sacos plasticos papelao esferovite etc ao alcance dos mesmos RECOMENDA ES PARA A INSTALA O important...

Page 26: ...a que o desliga apagando a chama do piloto sempre que a ventila o do local insuficiente ou a concentra o de CO2 excede o m ximo da norma Legal normal que o dito dispositivo actue em locais muito pequ...

Page 27: ...3 Mantenha pressionado o controlador de pot ncia durante 10 segundos 4 Pressione as piezoel ctricos bot o v rias vezes enquanto ainda mantendo o comando de pot ncia Uma vez que a chama est acesa mante...

Page 28: ...o ANTES DE AVISAR O SERVI O T CNICO O calor fero n o acende Verifique se h g s na garrafa e se o redutor est correctamente ligado e na posi o de aberto Verifique se o tubo flex vel est ligado Verifiqu...

Page 29: ...da temperatura interior pot ncia calor fica m nima elmin 0 kW Em duas ou mais fases manuais sem comando da temperatura interior Em estado de vig lia elSB 0 kW Com comando da temperatura interior por...

Page 30: ...n TYPE OF GAZ G30 Gas bottle Max Gas Weight 15 Kg Max Diameter 30 cm Max height 65 cm Pressure 30 37 mbar Consumption 110 305gr h Fran ais CE 1008 16 Cat I3 Puissance maximale 4 2kW Injecteurs 1 5 kW...

Page 31: ...HCE 74 31...

Page 32: ...HCE 74 32...

Reviews: