A.
Air inlet grille
B.
Air outlet grille
C.
Selector switch
D.
Thermostat knob
E.
Control lamp
F.
Anti-tilt switch protector
INSTRUCTIONS FOR USE
The selector switch and the thermostat knob enable you to select the following functions:
Selector switch:
Ο
: OFF. Both the fan and the two heating elements are switched off
: “Cool air”. Only the fan is switched on
I : “Warm air for gradual heating-up. ECO position (900 W): the fan and one of the heating elements
are switched on.
II : “Hot air” for quick heating-up. Full power (1800 W): the fan and the two heating elements are
switched on.
Thermostat knob:
With the thermostat knob you can set a constant room temperature. When the selector switch is set to
position I or position II the heater will automatically switch on as soon as the room temperature falls below
the set temperature.
As soon as the set temperature falls is reached, the switch will turn off.
Rotate the knob clockwise to obtain a higher temperature setting or anti-clockwise for a lower temperature
setting.
You may adjust the thermostat during use.
OVERHEATING SAFETY DEVICE
To prevent damage and risks due to overheating, the built-in overheating safety device cuts off the power
as soon as the heating elements become too hot.
MAINTENANCE
-
Before undertaking any maintenance operation, disconnect the appliance from the power supply.
-
This appliance does not require any particular maintenance. For cleaning it is recommended to use a soft
moist rag and neutral detergent. Do not use an abrasive cloth or devices which could affect the outward
appearance of the appliance. Check that the parts exposed to the heat rays and the ventilation are free of
dust and dirt.
During cleaning, be careful not to touch the quartz heating elements.
-
In case of breakdown and/or poor function of the appliance, disconnect the appliance from the power
supply and contact an authorized service center. Always request the use of original spare p arts.
The non-observation of these instructions can compromise the safety of the appliance and render guaranty
invalid.