OPTIMOD-AM 9200
VERSION 3.0 SOFTWARE ADDENDUM
A-5
System Setup Page 2:
ST
CHASSIS
NO
NITE MODE
ENABLED
DAY/NITE
DAY
System Setup Page 3:
POS PEAK
100%
NITE MODE POS PEAK
100%
Security and Passcode Programming
[Skip this section if you do not wish to change the security level of program passcodes at
the time and you are not using 9200 PC Remote software.]
The 9200 has a relatively simple security system. The same passcode is used for
local and remote security. If you plan to use 9200 PC Remote software, you
must
set a passcode so that the software can connect to your 9200. If you do not plan to
use 9200 PC Remote software, setting a passcode is optional.
A timer that locks out the front panel after a certain period of control inactivity
achieves local protection of the 9200. The
LOCKOUT
soft button activates this fea-
ture.
Programming a Passcode
To program a passcode, complete the following steps:
1.
Program the passcode
A)
Press the
Setup
button
to access security controls
.
I/O
CALIB
REMOTE &
SECURITY
TEST BAND
WIDTH
B)
Press the
REMOTE & SECURITY
soft button to access
SET PASSCODE.
SET MODEM
INIT
REMOTE
INTERFACE
SET
PASSCODE
LOCKOUT
Off
C)
Press the
SET PASSCODE
soft button to access the Set Passcode screen.
SELECT CHARACTER WITH KNOB
SAVE
PASSCODE
D)
Turn the knob until the desired number appears.
A passcode can have one to eight numbers. Embedded spaces are not al-