A confirmation dialog appears.
Click OK to clear the entries.
▼
How to Clear Faults From the System Event Log Using the ILOM
Command-Line Interface
Type the following command:
cd /SP/logs/event/
set clear=true
A confirmation message appears.
Type one of the following:
■
To clear the entries, type:
y
■
To cancel clearing the log, type:
n
Interpreting Event Log Time Stamps
The time stamps in the event log are related to the service processor clock settings. If the clock
settings change, the change is reflected in the time stamps.
When the service processor reboots, the SP clock is set to Thu Jan 1 00:00:00 UTC 1970.
The SP reboots as a result of the following:
■
A complete system unplug/replug power cycle
■
An IPMI command; for example,
mc reset cold
■
A command-line interface (CLI) command; for example,
reset /SP
■
ILOM web interface operation; for example, from the Maintenance tab, selecting Reset SP
■