Important – Install Latest OS Updates, Patches, and Firmware
■
From the CLI, at the command prompt (->) type:
show /System/Firmware
For more details, refer to information about viewing system information and inventory
in your server administration guide, which is available at
.
2.
Ensure that the firmware version is at the minimum required version, noted
above, or a subsequent release, if available.
3.
If the required firmware version (or newer) is not installed:
a.
Download the firmware from My Oracle Support at
Broken Link (Target ID: GQCYZ)
.
b.
Install the downloaded firmware.
Refer to the information about performing firmware updates in the
Oracle ILOM
Administrators Guide for Configuration and Maintenance
, which is available at
//www.oracle.com/goto/ilom/docs
. Ensure that you perform the preparatory steps
described in that document before updating the firmware.
Note -
Occasionally after installing the firmware, the Oracle ILOM web interface cannot
display the power state correctly on the power control page. To correct this problem, clear your
browser cache before logging in to the Oracle ILOM web interface.
Hardware Important Operating Notes
■
“SP Might Reboot Under Heavy Workload ” on page 14
■
“Diagnosing SAS Data Path Failures on Servers Using MegaRAID Disk
SP Might Reboot Under Heavy Workload
The service processor (SP) on the Sun Fire X4170 M2 Server or Sun Fire X4270 M2 Server
might reboot under a heavy workload due to lack of memory caused by a Sun Fire X4170 M2/
X4270 M2 Oracle ILOM memory limitation.
To prevent SP reboots from occurring when upgrading to Oracle ILOM 3.2.x.x, or later (or to
prevent SP reboots on a system already upgraded to Oracle ILOM 3.2.x.x, or later), follow these
guidelines:
14
Sun Fire X4170 M2 and X4270 M2 Servers Product Notes • July 2018