Lock the Robot and Remove Expansion Modules
Before removing the Base Module, the robot must be parked and locked. All
Expansion Modules below the Base must be removed.
Removing and replacing the Base Module can only be performed by an Oracle Service
representative.
1.
.
2.
Remove all modules below the Base Module.
See
.
Remove Base Chassis and Parts for Reuse
Remove functional components for reuse before removing the Base Module chassis.
1.
Remove the following applicable parts from the Base Module:
•
Unlock and Remove the Magazines
•
•
•
•
Remove the Power Supply Slot Cover
•
Remove the Front Control Panel
•
2.
Remove the screws securing the Base Module to the front of the rack.
WARNING:
The Base Module weighs approximately 12.8 kg (28.3 pounds) without
magazines, tape drives, power supplies, or the robot CRU. Two people
should lift the unit.
3.
Extract the module from the rack.
Replace the Base Module Chassis
Replacing the Base Module is very similar to installing a new Base Module.
•
Install the Base Module into the Rack
•
Install the Base Module CRUs and Expansion Modules
•
Reinstall Magazines and Dress the Cables
Install the Base Module into the Rack
The Base Module mounts into a standard 19-in rack.
Chapter 10
Base Module Chassis Removal and Replacement (FRU)
10-23