Servicing the Battery
The battery is a cold-service component that can be replaced by a customer. For the location of
the battery, see
“Processor Module Components” on page 18
.
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause failure of server components.
■
“Replace the Battery” on page 129
■
“Verify the Battery” on page 132
Replace the Battery
1.
Prepare the host for battery replacement.
To correctly reset the date and time before replacing a battery, you must revent the host from
automatically powering on and disable any NTP connections.
a.
Check the
HOST_AUTO_POWER_ON
property.
->
show /SP/policy HOST_AUTO_POWER_ON
Properties:
HOST_AUTO_POWER_ON = enabled
b.
If enabled, set the
HOST_AUTO_POWER_ON
property to
disabled
.
->
set /SP/policy HOST_AUTO_POWER_ON=disabled
c.
Check the NTP policy for the
/SP/clock
.
->
show /SP/clock usentpserver
Properties:
usentpserver = enabled
d.
If enabled, set the property to
disabled
.
->
set /SP/clock usentpserver=disabled
Servicing the Battery
129
Summary of Contents for SPARC T8-4
Page 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Page 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Page 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Page 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Page 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Page 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Page 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Page 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Page 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Page 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...