Log In to Oracle ILOM (Service)
No.
LED
Icon or Label
Description
6
AC 2 (left) and AC 3 (right)
power LEDs
Indicates these conditions:
■
Off
– No power is applied to the server.
■
Green
– Power is applied to the server.
7
Locator LED and button
(white)
Turn on the Locator LED by pressing the Locator button, or see
“Locate the Server” on page 49
. When lit, the LED blinks rapidly.
8
Server Service Required
LED (amber)
The
fmadm
faulty
command provides details about any faults that
cause this indicator to light. See
.
Under some fault conditions, individual component fault LEDs are lit
in addition to the Service Required LED.
9
Power OK LED (green)
Indicates these conditions:
■
Off
– Server is not running in its normal state. System power might
be off. The SPM might be running.
■
Steady on
– Server is powered on and is running in its normal
operating state. No service actions are required.
■
Fast blink
– Server is running in standby mode and can be quickly
returned to full function.
■
Slow blink
– A normal but transitory activity is taking place. Slow
blinking might indicate that system diagnostics are running or that
the system is booting.
10
SP LED
SP
Indicates these conditions:
■
Off
– AC power might have been connected to the power supplies.
■
Steady on, green
– SPM is running in its normal operating state.
No service actions are required.
■
Blink, green
– SPM is initializing the Oracle ILOM firmware.
■
Steady on, amber
– An SPM error has occurred and service is
required.
11
Overtemp LED(amber)
Indicates these conditions:
■
Off
– Indicates a steady state, no service action is required.
■
Steady on
– Indicates that a temperature failure event has been
acknowledged and a service action is required.
Log In to Oracle ILOM (Service)
1.
At the terminal prompt, type:
ssh root@
IP-address
Password:
password
Oracle (R) Integrated Lights Out Manager
Version 3.2.1.2 rXXXXX
32
SPARC T7-4 Server Service Manual • May 2017
Summary of Contents for SPARC T7-4
Page 1: ...SPARC T7 4 Server Service Manual Part No E54994 07 May 2017 ...
Page 2: ......
Page 10: ...10 SPARC T7 4 Server Service Manual May 2017 ...
Page 12: ...12 SPARC T7 4 Server Service Manual May 2017 ...
Page 86: ...86 SPARC T7 4 Server Service Manual May 2017 ...
Page 98: ...98 SPARC T7 4 Server Service Manual May 2017 ...
Page 110: ...110 SPARC T7 4 Server Service Manual May 2017 ...
Page 124: ...124 SPARC T7 4 Server Service Manual May 2017 ...
Page 142: ...142 SPARC T7 4 Server Service Manual May 2017 ...
Page 164: ...164 SPARC T7 4 Server Service Manual May 2017 ...
Page 192: ...192 SPARC T7 4 Server Service Manual May 2017 ...
Page 200: ...200 SPARC T7 4 Server Service Manual May 2017 ...
Page 208: ...208 SPARC T7 4 Server Service Manual May 2017 ...