Clear a Fault
Clear a Fault
When PSH detects faults, the faults are logged and displayed on the console. In most cases,
after the fault is repaired, the corrected state is detected by the server, and the fault condition
is repaired automatically. However, this repair should be verified. In cases where the fault
condition is not automatically cleared, you must clear the fault manually.
1.
After replacing a faulty FRU, power on the server.
2.
At the host prompt, determine whether the replaced FRU still shows a faulty
state.
.
■
If no fault is reported, you do not need to do anything else. Do not perform
the subsequent steps.
■
If a fault is reported, continue to
.
3.
Clear the fault from all persistent fault records.
In some cases, even though the fault is cleared, some persistent fault information remains
and results in erroneous fault messages at boot time. To ensure that these messages are not
displayed, type this PSH command:
#
fmadm acquit
event-ID
4.
If required, reset the server.
In some cases, the output of the
fmadm faulty
command might include this message for the
faulty component:
faulted and taken out of service
If this message appears in the output, you must reset the server after you manually repair the
fault.
->
reset /SYS
Are you sure you want to reset /SYS?
y
Resetting /SYS ...
Related Information
■
■
Detecting and Managing Faults
49
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...