Install the Fan Board
b.
Remove the two screws on each side of the outside of the chassis that hold
the fan board in place and unplug the fan board and power cables from
motherboard (panel 2).
c.
Remove the front memory riser guide by pulling it up and out of the chassis
(panel 3).
d.
Pull the fan board back and out of chassis (panel 4).
The circuit board and the fan holder portions of the fan board should remain together.
6.
Install a new fan board.
“Install the Fan Board” on page 137
Related Information
■
“Install the Fan Board” on page 137
Install the Fan Board
1.
Remove the fan board.
“Remove the Fan Board” on page 135
.
2.
Unpack the replacement fan board and place it on an antistatic mat.
3.
Remove the fan board cable and power cables from the faulty fan board and plug
the cables into the fan board on the replacement fan board.
Servicing the Fan Board
137
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...