Install the Motherboard
Install the Motherboard
Installing the motherboard is a cold-service operation. You must power off the server before
installing the motherboard.
1.
Consider your first step.
■
If you are replacing the motherboard, remove the faulty or obsolete motherboard first, then
.
See
“Remove the Motherboard” on page 230
.
■
If you are installing the motherboard as part of another component's removal or installation
2.
Position the motherboard for installation into the chassis.
The heatsinks are toward the front of the chassis, and the ports are at the rear.
3.
Lift the motherboard by the handles and slowly move the motherboard rearward
until the connectors slighty protrude through the rear of the chassis.
4.
Lower the motherboard onto the bottom alignment pins.
Servicing the Motherboard
233
Summary of Contents for netra X5-2
Page 1: ...Netra Server X5 2 Service Manual Part No E53601 03 October 2016 ...
Page 2: ......
Page 12: ...12 Netra Server X5 2 Service Manual October 2016 ...
Page 20: ...20 Netra Server X5 2 Service Manual October 2016 ...
Page 59: ...Using the Server Fault Remind Button Detecting and Managing Faults 59 ...
Page 60: ...60 Netra Server X5 2 Service Manual October 2016 ...
Page 128: ...128 Netra Server X5 2 Service Manual October 2016 ...
Page 144: ...144 Netra Server X5 2 Service Manual October 2016 ...
Page 148: ...148 Netra Server X5 2 Service Manual October 2016 ...
Page 154: ...154 Netra Server X5 2 Service Manual October 2016 ...
Page 180: ...180 Netra Server X5 2 Service Manual October 2016 ...
Page 210: ...210 Netra Server X5 2 Service Manual October 2016 ...
Page 226: ...226 Netra Server X5 2 Service Manual October 2016 ...
Page 266: ...266 Netra Server X5 2 Service Manual October 2016 ...
Page 274: ...274 Netra Server X5 2 Service Manual October 2016 ...