Remove the PDB
Remove the PDB
Removing the PDB is a cold-service operation. You must power off the server before you
remove the PDB.
1.
Prepare for service.
“Preparing for Service” on page 43
.
2.
Review this information and complete these prerequisites in this order.
See:
■
“Remove a Power Supply” on page 134
Remove both power supplies.
■
“Remove the Filter” on page 79
■
“Remove a Fan Module” on page 153
Remove all fan modules.
■
“Remove the Fan Tray” on page 69
■
“Rotate the Drive Cage to the Service Position” on page 71
■
“Remove the Air Duct” on page 75
■
“Remove the PSU Duct” on page 74
■
“Remove a PCIe Card” on page 174
■
“Remove the Internal HBA PCIe Card” on page 179
3.
Disconnect the cables from the motherboard.
4.
Open the cable tie on the right side of the chassis, and disconnect the LED
assembly cable.
5.
Remove the right thumb screw bracket.
6.
Disconnect the cable from the PDB.
Servicing the PDB
143
Summary of Contents for Netra SPARC S7-2
Page 1: ...Netra SPARC S7 2 Server Service Manual Part No E73207 03 February 2017 ...
Page 2: ......
Page 12: ...12 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 24: ...24 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 42: ...Server Fault Remind Button Operation 42 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 84: ...84 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 108: ...108 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 140: ...140 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 150: ...150 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 158: ...158 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 192: ...192 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 216: ...216 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 258: ...258 Netra SPARC S7 2 Server Service Manual February 2017 ...