Remove Fabric Interconnect F1-15 Power Supplies
Caution -
When replacing the Power Supplies: - wear an ESD wrist strap - When the hardware
is out of its shipping package or not in the Fabric Interconnect chassis, make sure you place it in
an ESD safe bag or on a grounded work surface such as a rubberized work mat.
See the appropriate section:
■
“Remove Fabric Interconnect F1-15 Power Supplies” on page 107
■
“Remove Fabric Interconnect F1-4 Power Supplies” on page 108
Remove Fabric Interconnect F1-15 Power Supplies
When you hot swap a Fabric Interconnect F1-15 PSU, the Fabric Interconnect polls for
hardware status every 30 seconds. Polling starts when the Fabric Interconnect senses a PSU
disconnect from the system's power channel.
When a PSU is disconnected, you must wait for at least 30 seconds before re-inserting it. This
30-second wait period is required to properly raise alarms and update the PSU part number,
serial number, and other pertinent information for the system's hardware inventory. When hot
swapping a PSU for a Fabric Interconnect F1-15, make sure to wait for more than 30 seconds
before re-inserting a PSU.
To remove and insert a Fabric Interconnect F1-15 power supply, follow this procedure:
1.
Using the screwdriver, loosen the locking screw in the PSU locking lever. See
Figure 65, “Loosening the Fabric Interconnect F1-15 PSU Lock Screw,” on page
.
FIGURE 65
Loosening the Fabric Interconnect F1-15 PSU Lock Screw
Performing Service Tasks
107
Summary of Contents for Fabric Interconnect F1-15
Page 1: ...Oracle Fabric Interconnect Hardware User s Guide Part No E50997 04 July 2016...
Page 2: ......
Page 8: ...Contents Index 173 8 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 10: ...10 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 94: ...94 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 168: ...168 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 172: ...172 Oracle Fabric Interconnect Hardware User s Guide July 2016...
Page 176: ...176 Oracle Fabric Interconnect Hardware User s Guide July 2016...