BIOS Advanced Menu Selections
236
Oracle Server X6-2 Service Manual • June 2016
Setup Options
Options
Defaults
Description
■ None: No parity bits
are sent.
■ Even: Parity bit is 0 if
the number of 1s in the
data bits is even.
■ Odd: Parity bit is 0 if
the number of 1s in the
data bits is odd.
■ Mark: Parity bit is
always 1.
■ Space: Parity bit is
always 0.
Mark and Space parity
do not allow for error
detection. They can be
used as an additional data
bit.
Stop Bits
1/2
1
Stop bits indicate the end
of a serial data packet.
(A start bit indicates the
beginning of a serial data
packet.) The standard
setting is 1 stop bit.
Communication with slow
devices may require more
than 1 stop bit.
Flow Control
None, Hardware RTS/
CTS, Software Xon/Xoff
None
Flow control can prevent
data loss from buffer
overflow. When sending
data, if the receiving
buffers are full, a 'stop'
signal can be sent to stop
the data flow. Once the
buffers are empty, a 'start'
signal can be sent to restart
the flow. Hardware flow
control uses two wires to
send start/stop signals.
BIOS Advanced Menu Trusted Computing Options
The following table lists the BIOS Advanced Menu Trusted Computing options.
TABLE 33
BIOS Advanced Menu Trusted Computing Options
Setup Options
Options
Defaults
Description
TPM Support
Disabled/Enabled
Disabled
Enable or disable Trusted
Platform Module (TPM)
support. Only UEFI BIOS
implements this setup
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...