Remove a Power Supply
58
Oracle Database Appliance Service Manual • February 2016
For information about power supply status LEDs, see
.
This section includes:
■
“Detecting a Power Supply Failure” on page 58
■
“Remove a Power Supply” on page 58
■
“Install a Power Supply” on page 59
Detecting a Power Supply Failure
The following LEDs light up when the system detects a power supply fault:
■
Front and rear Service Required LEDs located on each server node
■
REAR HDD/PS/FAN LED located on the front of each server node
■
Service Required LED located on the faulty power supply
See
“Server Node Status Indicators” on page 17
on page 1-6 for information about these LEDs.
Remove a Power Supply
Caution -
Hazardous voltages.
To reduce the risk of electric shock and danger to personal
health, follow the instructions.
1.
Identify which power supply (0 or 1) requires replacement.
A lit Service Required LED on a power supply indicates that a failure was detected. For
information about power supply status LEDs, see
“Power Supply Status Indicators” on page 21
.
2.
Disconnect the power cord from the faulty power supply.
3.
Grasp the power supply handle and press the release latch [1]).
Summary of Contents for Database Appliance X3-2
Page 1: ...Part No E69614 01 February 2016 Oracle Database Appliance Service Manual...
Page 2: ......
Page 8: ...8 Oracle Database Appliance Service Manual February 2016...
Page 26: ...26 Oracle Database Appliance Service Manual February 2016...
Page 38: ...38 Oracle Database Appliance Service Manual February 2016...
Page 86: ...86 Oracle Database Appliance Service Manual February 2016...
Page 136: ...136 Oracle Database Appliance Service Manual February 2016...
Page 148: ...148 Oracle Database Appliance Service Manual February 2016...
Page 178: ...178 Oracle Database Appliance Service Manual February 2016...
Page 188: ...188 Oracle Database Appliance Service Manual February 2016...