background image

 

 
 
 
 
 
 
 

Switch-selectable capacitance for cartridge termination  

 

Another 6 positions rotary switch is used for the selection of termination capacitance for the MM and MC.  
 
You can change their capacitance by turning the rotary knob on the front panel for best suitable capacitance. 
Careful listening is recommended for the decision of this capacitance setting between 33 PF and 1000 PF. 

 

Capacitance: 0, 33,100,220,470, 1000 PF  6 positions selectable 
 
 

Set-up transformers for MC cartridge 

 

For a realistic experience within the finest world of analog, the Oracle Temple phono stage has adopted the 
Sweden made Lundahl separate transformers for the MC stage. (Left & right). This unique combination will draw 
every details and dynamics from your Oracle Temple PH 1000. 
 
 

RIAA Equalization 

 

The RIAA circuit is designed by following the true RIAA standard. 
The accuracy of RIAA standard curve is +/- 1dB, 
 
 

Low Cut Filter 

 

The low cut filter button is used to cut the low frequency. This will prevent any rumbling and will also protect the 
speakers 
 
 

Ultra-high Grade components 

 

All the components used in the Oracle Temple PH 1000 phono stage are ultra-high grade. These components 
are used for higher Signal to Noise ratio and for a better musicality. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Oracle Audio Technologies 

PH 1000 Temple Phono stage 

6

Summary of Contents for Temple PH 1000

Page 1: ...g x Y x T y c t z v Oracle Audio Technologies PH 1000 Temple...

Page 2: ...portance of the different key adjustments Your TEMPLE is a precision instrument and its performance will be affected by the different adjustments It is important to set up your TEMPLE with the utmost...

Page 3: ...TABLE OF CONTENTS Introduction 4 Features 5 Connection procedure 8 Operating Instruction 9 Specifications 11 Oracle Audio Technologies PH 1000 Temple Phono stage 3...

Page 4: ...perfect music recording medium with high fidelity and musicality From the very first moment you experience the design functionality and control of the Oracle Temple PH 1000 phono stage you will bette...

Page 5: ...ent stages gain setting by using this knob you will be able to meet many cartridges specifications You will also be able to set the gain depending on the output from the cartridges from 40dB up to 60...

Page 6: ...the Oracle Temple phono stage has adopted the Sweden made Lundahl separate transformers for the MC stage Left right This unique combination will draw every details and dynamics from your Oracle Templ...

Page 7: ...se the input impedance rotary switch doesn t affect the loading impedance y Low Impedance MM and MC cartridge load setting These two types of cartridges should be connected through the MC1 or MC2 RCA...

Page 8: ...o unbalanced RCA inputs from your turntable Main Output These outputs are to be connected to your preamplifier or integrated amplifier The Oracle Temple PH 1000 phono stage is working unbalanced and b...

Page 9: ...f the Oracle Temple phono stage The LED OFF state is original polarity Mono Whenever you press MONO button the indication LED changes On and OFF to show the status of the Oracle Temple phono stage The...

Page 10: ...s selection rotary switch doesn t affect MM input Only for MC1 and MC 2 inputs 1 25 2 50 3 100 4 200 5 330 6 470 Ohms Input The Oracle Temple PH1000 has 3 inputs MM MC1 MC2 Gain Use this rotary switch...

Page 11: ...SPECIFICATIONS Oracle Audio Technologies PH 1000 Temple Phono stage 11...

Page 12: ...st be supplied for all warranty services Any unauthorized work modification or service rendered on the Oracle Temple PH 1000 phono stage will void the warranty We are confident your new Oracle product...

Reviews: