Appliance designed, tested and manufactured according to:
•
Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC 62233.
•
Performance: EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO 5168; EN/IEC 60704-1; EN/IEC 60704-2-13;
ISO 3741; EN 50564; IEC 62301.
•
EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2; EN/IEC 61000-3-2; EN/IEC 61000-3-3.
Suggestions for a correct use in order to reduce the environmental impact: Switch ON the hood at
minimum speed when you start cooking and kept it running for few minutes after cooking is finished.
Increase the speed only in case of large amount of smoke and vapour and use boost speed(s) only in
extreme situations. Replace the charcoal filter(s) when necessary to maintain a good odour reduction
efficiency. Clean the grease filter(s) when necessary to maintain a good grease filter efficiency. Use the
maximum diameter of the ducting system indicated in this manual to optimize efficiency and minimize
noise.
Additional Installation Specifications:
Use only the fixing screws supplied with the product for installation or, if not supplied, purchase the
correct screws type. Use the correct length for the screws which are identified in the Installation Guide.
In case of doubt, consult an authorised service assistance centre or similar qualified person.
WARNING!
Failure to install the screws or fixing device in accordance with these instructions may result
in electrical hazards.
USE
The hood is designed to be used either for exhausting or filter version.
DUCTING VERSION
In this case the fumes are conveyed outside of the building by means of a special pipe connected with
the connection ring located on top of the hood.
Attention!
The exhausting pipe is not supplied and must be purchased apart. Diameter of the exhausting
pipe must be equal to that of the connection ring.
In the horizontal runs the exhausting pipe must be slightly slanted (about 10°) and directed upwards to
vent the air easily from the room to the outside.
Attention!
If the hood is supplied with active charcoal filter, then it must be removed.
Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (connection
flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the
suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct as smooth as possible inside.
!
The duct must be made of certified material.
Summary of Contents for gorenje S1 BHP643ORAB
Page 1: ...S1 BHP643ORAB S1 BHP643ORAW DETAILED INSTRUCTIONS FOR USE OF THE KITCHEN HOOD...
Page 4: ...1 2 A 100 160 16 cm 10 cm 16 cm 1 cm 7 11 9 8 12a 10...
Page 5: ...4x 3 9x9 5mm min 10 max 50 13a 12b 14a 13b 14b 15b...
Page 6: ...4 szt 1 16b 18 17 19 4 20 21...
Page 7: ...LED JDR GU10 3W LED JDR GU10 3W 22 23...
Page 8: ...BG 8 BG...
Page 10: ...BG 10 50cm 65cm G G...
Page 13: ...BG 13 10 90...
Page 49: ...GE 49 GE...
Page 51: ...GE 51 50 65 III...
Page 53: ...GE 53 3 ON OFF T7 T8 3 T8 5 T8 5 ON OFF T3 5 1 3 5 3 5...
Page 54: ...GE 54 LED LED 10 90...
Page 65: ...KK KK 65 KK 2012 19 WEEE...
Page 67: ...KK 67 50cm 65cm 3 5 15...
Page 69: ...KK 69 ON OFF T3 5 1 T3 5 T3 5 4 10 90...
Page 80: ...MK MK 80 MK 2012 19 EC Waste Electrical and Electronic Equipment WEEE...
Page 82: ...MK 82 50cm 65cm III...
Page 84: ...MK 84 T7 T8 T7 T6 16 T8 T7 26 ON OFF T3 5 1 T3 5 T3 5 4 LED LED 10 90 T6 T7 T8 16 mm 26 mm...
Page 95: ...RU 95 RU...
Page 97: ...RU 97 50cm 65cm 3...
Page 99: ...RU 99 T7 T8 3 T8 5 T8 5 T7 T8 T7 T6 16 T8 T7 26 T3 5 1 T3 5 T3 5 4 T6 T7 T8 16 mm 26 mm...
Page 100: ...RU 100 LED 10 90 720 16 06 97 10...
Page 125: ......
Page 126: ......
Page 127: ......