OPW Installation, Operation and Maintenance Manual, Page 44 Executive Order VR-401-C
from the vantage point it will be viewed from in day-
to-day operations to properly calibrate the gears.
(See Figure 3.)
Figure 3
Step 11
Place the lid gasket back into the groove, being
careful not to damage it and keep it clean from
debris. No sealant is necessary for this gasket. Add
the cover and secure it tightly with the eight (8)
bolts, using a crossing pattern, torque the bolts to
15-20 ft-lbs.
Annual Maintenance:
Using a dip stick, measure the liquid level of the
tank and check this value with the value displayed
on the tank gauge. The values should be within ±2
inches of each other. Recalibrate if necessary.
Remove cover and visually inspect the internal
parts for signs of wear, tangles in the spool, and
corrosion. Replace parts if necessary.
9393 Princeton-Glendale Road, Cincinnati, Ohio 45011
1-800-422-2525 Domestically
513-870-3315 Internationally
www.opw-fc.com
Copyright, 2009
OPW Fueling Components Inc., Cincinnati, OH
Printed in U.S.A. p/n H14912PA – 07/09
Slide Gears toward spring to Disengage