UMX-ETH+   version 4.3.000 EN 

Expansion IP card 

for UMX-03/0 audio matrix 

UMX-ETH+ 

 

5.

 

COMMISSIONING THE UNIT 

To commission the UMX-ETH+ card we must send configurations to it via an Ethernet connection. Accomplishing this requires a PC 

equipped with a network card and connected to the unit through a switch or directly using a network cable. The PC must have the 

PA Manager 4.3 

software installed. 

1.

 

Place the card in the UMX-03/0 audio matrix. 

2.

 

Connect the devices to the network (PC and UMX-ETH+). 

2.  Power the devices (UMX-03/0). 
3.

 

Via the 

PA Manager 

software, configure the parameters of the UMX-ETH+. 

4.

 

Connect  the  equipment:  In the structure of the installation, right click with the mouse on the UMX-ETH+  card  and select 

Connect Equipment

5.

 

Open the 

File 

menu and select 

Save

6.

 

Send the settings to the UMX-ETH+. In the structure of the installation, right click with the mouse on the UMX-ETH+ card and 

select the option 

Send Configurations

 
 
 
 
 
 
 
 
 
 
 
 

5.1.

 

Configuration of the UMX-ETH+ network addresses 

To change the unit's network settings by default, carry out the following: 
1.

 

From the PC, open a browser, enter the IP address for the UMX-ETH+ card  and press INTRO. By default the IP address is 

10.1.1.1. 

Warning:

 The range of IP addresses for the unit and the PC must match. Otherwise, the network settings of the PC 

must be changed first in order to place it within the range of the unit (for example, the PC could have an IP address of 

10.1.100.152). 

2.

 

Enter the user name 

optimax

, the password 

1933

 and click on the 

Login

 button. This is the default password. For security, from 

PA Manager 4.3 software it must be changed by installer. 

3.

 

Click on 

Network

4.

 

Modify the network parameters as desired (

IP

Netmask

 and 

Gateway

) and click on the 

Change Network Settings

 button to 

apply the changes. 
The equipment will reboot automatically. 

 

 

 

 

ATTENTION 
To send configurations to the unit requires having the unit and the PC within the same IP address range. The unit's net-

work addresses and those set via the configuration software must match. 

By default, the network configurations of the unit are the following: 
 

 

IP ADDRESS:  10.1.1.1 

 

 

NETMASK:   

255.0.0.0 

 

 

GATETEWAY:  0.0.0.0 (without Gateway) 

If you wish to assign a different network address to the equipment, other than the one established by default, refer to the 

following sectio

5.1. Configuration of the UMX-ETH+ network addresses.

 

 

Summary of Contents for UMX-ETH+

Page 1: ...9I012M May 2018 V4 3 000...

Page 2: ......

Page 3: ...MISSIONING THE UNIT 7 5 1 Configuration of the UMX ETH network addresses 7 6 OPTIMAX2 SYSTEM NETWORK SPECIFICATIONS 8 7 TECHNICAL SPECIFICATIONS 10 8 SOFTWARE AND FIRMWARE VERSIONS 10 9 DOCUMENT VERSI...

Page 4: ...e operation of the equipment using software and or basic TELNET or SSH Secure Shell functions Each card occupies one position on the bus of a UMX 03 0 Files download by means of FTP or FTP S 2 ELEMENT...

Page 5: ...g periods remove the battery Remove leaking batteries from the device immediately If battery acid leaks out it is essential to avoid contact with the skin eyes and mucous membranes If the acid does co...

Page 6: ...o insert the card proceed as follows 1 Disconnect the power supply to the unit POWER SUPPLY 1 and POWER SUPPLY 2 strips 2 Remove the rear blank plate for the slot where the card is to be inserted 3 In...

Page 7: ...C open a browser enter the IP address for the UMX ETH card and press INTRO By default the IP address is 10 1 1 1 Warning The range of IP addresses for the unit and the PC must match Otherwise the netw...

Page 8: ...crophone to the Optimax 2 matrixes point to multipoint communication VoIP OPTIMAX2 matrix allows to work also like a receiving VoIP terminal one call each time as following standards Call establishing...

Page 9: ...ON TCP unicast 28000 Integration SNMP UDP unicast 161 162 TRAPS Integration SIP UDP unicast 5060 Control 5078 RTP Audio Specifications of the local network LAN Bandwidth 1 Mb for each audio channel Nu...

Page 10: ...03 0 Consumption 300 mA 8 SOFTWARE AND FIRMWARE VERSIONS The functionalities described in this user manual are valid for software and firmware versions that are the same or later versions of UMX ETH F...

Page 11: ...e of the equipment including lack of maintenance 5 The guarantee shall not be valid whenever the following is observed Amendments or corrections made to the details of the guarantee certificate or pur...