background image

 

 

MD-30C version 3.2.000 

11 

Microphone  desk and 

voice alarm fireman's panel 

ME-200C 

6.

 

COMMISSIONING THE UNIT 

Commissioning the unit requires sending of configurations to the COMPACT audio matrix to whose CAN bus the ME200C is con-

nected. To do this, you need a PC equipped with a network card and connected to the COMPACT matrix, either through an Ethernet 

switch, or directly through a network cable. The PC must have the 

Call Point

 software installed. 

1.  Set the CAN address of the ME-200C and its position in the BUS (end or intermediate element) according to section 

4. 

CONFIGURATIONS

2.   Make the connections between units. 
3.  Apply power to the units. 

4.  Via the 

Call Point

 software, configure the parameters of theME-200C and send the configurations to the COMPACT unit. 

7.

 

WORK MODES 

There are two distinct work modes: Normal and Emergency modes. Normal mode is the default working mode. Using a key switch 

accesses Emergency Mode. 

Normal Mode: 

It allows you to send live messages and replays of those messages. The destination zones of the messages are predetermined via 

the 

Call Point

 software. 

Emergency Mode: 

It has a warning message push-button, an evacuation message push-button and microphone for live messages. Access to the emer-

gency mode is protected by a key switch. 
The WARNING and EVACUATION messages are assigned and configured via the 

Call Point

 software 

All the emergency messages (live messages as well as pre-recorded WARNING and EVACUATION messages) will be broadcast to the 

Associated Group

. The 

Associated Group

 must have been previously configured via the 

Call Point

 software. 

 

NORMAL MODE 

EMERGENCY MODE 

Default mode 

Access to emergency mode with key switch  

Messages are sent to the predetermined zones previously 

configured via 

Call Point

 software 

Messages are sent to the 

Associated Group

 (predetermined 

group via 

Call Point

 software) 

Allows live voice messages 

There is a REPEAT key whose function is to repeat the last live message. 

WARNING push-button non operative 

WARNING push-button activates the warning message 

EVACUATION push-button non operative 

EVACUATION push-button activates the evacuation message 

RESET push-button non operative 

RESET push-button to exit emergency mode 

8.

 

NORMAL MODE OPERATIONS 

8.1.

 

Sending a live voice announcement 

1  Press and hold 

GONG+TALK

 (or 

TALK

). 

2  You can begin speaking when the blue TALK LED 

illuminates. 

3  To finish the broadcast, release the 

GONG+TALK 

(or 

TALK

). 

 

8.2.

 

Repeat function 

The microphone desk incorporates a function that enables to 

repeat the last live voice message that was sent.  
To  activate select the 

REPEAT

  key. The TALK/REPEAT 

indicator light remains illuminated while the message is being 

repeated. 
You can stop a repeat message that is being played by press-

ing the 

REPEAT

 key again. 

Summary of Contents for ME-200C

Page 1: ...9I327 17 03 2017 V3 1 000...

Page 2: ......

Page 3: ...9I327 16 10 2018 V3 2 000...

Page 4: ...NORMAL MODE OPERATIONS 11 8 1 Sending a live voice announcement 11 8 2 Repeat function 11 9 OPERATIONS IN EMERGENCY MODE 12 9 1 Entering the Emergency Mode 12 9 2 Activatinga WARNING message 12 9 3 Ac...

Page 5: ...microphone capsule error or communicationerror withaudiomatrix LEDs in dicators Acoustic alarm indicator Microphone audio level indicator Powered by 24V DC Every COMPACT matrix unit allows connecting...

Page 6: ...the paging desk 14 LOCAL FAULT LED Indicatesmicrophone capsule error or communication error with audio matrix 15 TALK REPEAT LED Illuminates when TALK or GONG TALK is pressed indicating that you can...

Page 7: ...N position Ifit is an intermediate element set them OFF DIP switches 5 6 7 and 8 CAN ADDRESS The microphone deskcommunicates with the COMPACT system through a CAN bus Each ME 200Cconnectedto the CAN b...

Page 8: ...ME 200C end element or intermediate element If the microphone desk is the final bus element set these DIPswitches to ON If it is an intermediate element set them OFF DIP switch 4 No used DIP switches...

Page 9: ...CAN bus connection Through the RJ45 INPUTand OUTPUTconnectors the console transmits and receives CAN communicationandaudiosignals to the COMPACT system For connection use RJ45 connectors with metal h...

Page 10: ...n Optimus Z 52A patch panel or similar 5 2 2 CAN Bus and audio connection between several ME 200C Use the INPUT and OUTPUT connectors to connect various up to a maximum of 16 forming a BUS between ele...

Page 11: ...ted in the bus to match the transmission speed betweendevices The attachedtable shows the transmission speed ofthe equipments To connect an ME 200Cto the COMPACT E follow figure 7 EQUIPMENT SPEED TRAN...

Page 12: ...EVACUATION messages are assigned and configured via the Call Point software All the emergencymessages live messages as well as pre recordedWARNINGandEVACUATIONmessages willbe broadcast to the Associat...

Page 13: ...y resume playing 9 4 Sending a live voice message in Emergency Mode 1 With the microphone desk in emergencymode press and hold the GONG TALK or TALK button 2 You can beginspeaking when the TALK indica...

Page 14: ...Illuminates when the microphone desk detects an internal application error firmware GENERIC FAULT indicator Front yellow LED Illuminates when the microphone desk receives one or several alarms from th...

Page 15: ...VERSIONS The functionalitiesdescribed inthis user manual are validfor software andfirmware versions that are the same or later versions of ME 200C Firmware Version5 11 COMPACT Firmware Applicationvers...

Page 16: ...f the equipment including lack of maintenance 5 The guarantee shall not be valid whenever the following is observed Amendments or corrections made to the details of the guarantee certificate or purcha...

Page 17: ...9I327 16 10 2018 V3 2 000...

Page 18: ......

Page 19: ...9I327 16 10 2018 V3 2 000...

Page 20: ...DE TRABAJO 11 8 OPERACIONES EN MODO NORMAL 11 8 1 Enviar unaviso de viva voz 11 8 2 Funci n de repetici n 11 9 OPERACIONES EN MODO EMERGENCIA 12 9 1 Entrar en Modo Emergencia 12 9 2 Activar un mensaj...

Page 21: ...error de comunicaci n con la matriz de audio Indicador ac stico de alarma Indicadores luminosos del nivel del micr fono Alimentaci n a 24V C C Cada unidad COMPACT permite la conexi n de 16 pupi tres...

Page 22: ...n 14 Indicador LOCAL FAULT Indica error de c psula del micr fono o error de comunicaci n conla matriz de audio 15 Indicador TALK REPEAT Se ilumina tras pulsar TALK o GONG TALK indicando que se puede...

Page 23: ...ata de un elemento inter medio sit elos en OFF DIP switches 5 6 7 y 8 CAN ADDRESS El pupitre se comuni ca con el sistema COMPACT a trav s de un bus CAN Cada pupitre conectado al bus CAN debe tener una...

Page 24: ...bus CAN Si el pupitre es el elemento final delbus sit e estos DIPswitches en ON Si se trata de unelemento intermedio sit elos en OFF DIP switch 4 No utilizado DIP switches 5 6 7 y 8 CAN ADDRESS El pu...

Page 25: ...s de comunicaci n CAN A trav s de los conectores RJ45 INPUTyOUTPUT el pupitre transmite yrecibe las se alesde audio yde comunicaci nCAN haciael sistema COMPACT Para su conexi n utilice conectores RJ45...

Page 26: ...Conexi n del audio y del bus de comunicaci n CAN entre pupitres ME 200C La combinaci nde los conectores INPUT y OUTPUT permitenla conexi n de varios pupitres ME 200C hasta unm ximode 16 pupitres form...

Page 27: ...AV para que concuerde la velocidadde transmisi n entre equi pos La tabla adjunta muestra la velocidadde transmisi nde cada equipo Para la conexi ndel pupitre ME 200Ca la unidad esclava COMPACT E siga...

Page 28: ...micr fonopara avisos de viva voz El acceso al modo de emergencia est protegido mediante un interruptor con llave Los mensajes de WARNING y EVACUATION se asignan y configuran mediante el software Call...

Page 29: ...iza se retoma autom ticamente la reproducci n del mensaje de EVACUATION 9 4 Enviar un mensaje de viva voz en Modo Emergencia 1 Con el pupitre enmodoemergencia pulse y mantenga apretado GONG TALK o TAL...

Page 30: ...Indicador luminosoCPU FAULT Led amarillo Se enciende cuando el pupitre detecta unerror internode la aplicaci n firmwa re Indicador luminosoGENERICFAULT Led amarillo Se enciende cuando el pupitre reci...

Page 31: ...VERSIONES DE SOFTWAREY FIRMWARE Las funcionalidadesdescritaseneste manual de usuariosonv lidaspara versiones de software yfirmware iguales o superiores a Firmware ME 200C Version 5 11 Firmware COMPAC...

Page 32: ...Los da os personales o a la propiedad que pudieran causar el uso indebido del equipo incluyendo la falta de mantenimiento 5 La garant a carecer de validez cuando se observe Enmiendas o tachaduras en l...

Page 33: ...9I327 16 10 2018 V3 2 000...

Reviews: