background image

 

Repair  works  must  only  be  carried  out  by  a  specialist/specialist 

workshop. 

 

If  you  have  queries  about  handling  the  device,  which  are  not 

answered  in  this  operating  instruction,  please  check  with  the 

distributor for further help.

                                                   

4. 

Power Supply 

The shipped power adapter is  the power supply for this charger. In case 

you need to use other power adapter, please be aware that power supply 

has the correct polarity plug. Also please be noted that power supply need 

be able to supply minimum 1.0A current. Low output power adapter could 

lead to working improperly.   

When charger is powered up, version number is displayed for 2s. Then all 

LCD  segments  will  light  up  momentarily.  “null”  will  be  shown  until  any 

batteries are inserted. 

 

5. 

Operation 

Once a rechargeable battery is inserted, its present voltage( for example, 

“1.12v”)  will  be  displayed  for  3  seconds,  then  400mA  default  charging 

current  will  be  shown  on  display  for  another  3  seconds.  If 

MODE

  or 

CURRENT 

button  is  not  pressed  during  these  6  seconds,  the  charging 

process will start. During the first 6 second time, If any button is pressed, 

the unit will wait for another 10s before finishing current slot setting. Once 

the first battery working mode has been entered, the next battery can be 

inserted  and  choosing  the  desired  working  mode  accordingly.  While  the 

previous  battery  slot  setting  mode  is  in  effective  (telling  by  the  flashing 

display of that battery slot LCD ), and the next battery is inserted, then both 

battery slot display will be flashing, which means that any setting change 

will be applied for all batteries in setting mode at the same time. 

Once normal working mode starts, charging current or working mode can 

no longer be changed until batteries are taken out from charger and insert 

into charger again, or mode button is pressed longer than 2 seconds.. 

During  normal  working  mode,  press  DISPLAY  button  will  toggle  display 

mode between battery  voltages,  working current,  elapsed time for all the 

slots in working progress.   

Each button pressed will turn on back light for 30 seconds. 

5.1 Mode Selection 

 

Press  and  hold  the  “MODE”  button  for  2  seconds  to  start  working 

mode selection for all four battery slot.   

 

Press  the  “MODE”  button  subsequently  to  toggle  among  the 

“Charge”, ”Discharge”, ”Test” , “Quick Test” and “Refresh” mode 

 

When particular slot working mode needs to be changed, detach the 

battery from charger and insert the battery into slot again, while that 

selected slot LCD display content is in flashing, press MODE button 

to choose desired working mode. 

 

When  working  mode  is  changed,  working  current  adjustment  is 

possible also. 

 

5.2 Current Selection 

Within the first 6 seconds after inserting the battery or right after power up, 

press  the  “CURRENT”  button  to  select  desired  charge  current  for  slots 

loaded  with  battery  at  the  same  time.  Current  setting  can  not  be  altered 

once the setting has been confirmed in the initial stage. If different working 

current  is  needed  afterwards,  either  changing  the  working  mode  or 

rechargeable  battery  must  be  taken  out  and  inserted  again.  Discharge 

current is automatically set to predefined charge current. 

Batteries for slot 1 and 4( no batteries present at slot 2 or 3), its charging 

current can be selected for 1000mA further. Slot 2&3 maximum charging 

current is limited to 700mA only. 

 

5.3 Display Selection 

“DISPLAY”  button  is  for  toggling  display  information  for  voltage,  current, 

capacity, work time etc. 

 

6. 

Overheat Protection 

With our improved charging circuit design, for normal good quality battery 

with low impedance, heating built up on battery during charging process is 

almost unnoticeable. However during the last charging stage, when battery 

is  almost  full,  batteries  can  become  warm.  This  is  normal:  the  larger 

charging  current  applied,  the  more  heat  will  build  up.  When  battery 

temperature  is  sensed  to  be  over  60C,  then  over  heat  protection  will  be 

kicked  in  for  safety  reason.  Beside  the  two  battery  temperature  sensor, 

there  are  also  two  temperature  sensors  located  on  controller  board, 

located  at  the  area  where  most  heat  is  generated.  So  both  battery  and 

controller temperature is monitored during the operation of the charger. 

 

When overheating occurs, either from battery over 60 degrees Celsius or 

controller board  over  77  degrees  Celsius,  current  working  mode  will  be 

automatically halted. If controller board over heat is detected, over heat 

protection will be applied for the corresponding 2 battery slots at the same 

time.  If  battery  temperature  over  heat  detected,  only  the  over  heated 

channel will be halted accordingly. To tell if it is in the state of overheating 

protection mode, charging current will be reduced to 0mA.   

Charging/discharging process will only resume after battery temperature 

drops  below  40  degrees  Celsius  and/or  charger  controller  board  drops 

below 50 degrees Celsius.   

 

 

     

Summary of Contents for BT-C700

Page 1: ... charger has its backlight turned on after each key press Back light will be switched off after 30 seconds when no key is pressed The maximum charging capacity can be up to 20 000mAH 2 Delivery Content Battery Charger BT C700 1pcs Power Adapter 1pcs Operation Instructions 1pcs Optional accessory Part 3 Safety Instructions We do not assume liability for resulting damages to property or personal inj...

Page 2: ...ing mode needs to be changed detach the battery from charger and insert the battery into slot again while that selected slot LCD display content is in flashing press MODE button to choose desired working mode When working mode is changed working current adjustment is possible also 5 2 Current Selection Within the first 6 seconds after inserting the battery or right after power up press the CURRENT...

Page 3: ...ys use batteries with close internal resistance range when they are used in serial to achieve maximum battery life Alkaline and any other 1 5v batteries can be tested on this charger as well If a completely empty battery is to be tested it is not possible to give any correct reading Please be noted that since the internal battery resistance can be very small and contact resistance can be a major i...

Page 4: ...e chemical symbols for the respective hazardous substances are Cd Cadmium Hg Mercury Pb Lead You can return used batteries rechargeable batteries free of charge to any collecting point of your local authority 10 Technical Data Официальный представитель компании Opus Instruments в Казахстане Интернет магазин www kupifonar kz e mail info kupifonar kz тел 8 727 296 97 64 Operating Voltage 12V 16VDC P...

Reviews: