8
Gather pairs, trim and carefully
insert into RJ45 plug:
Crimp wires in place using a
professional quality crimping tool
to ensure a secure connection:
1. Using a single Cat5e cable, connect the AMR650-A to the
MCU300 via an RJ45 plug at the Master Control Unit, and the 8-
way colour-coded punch down connection at the AMR650-A.
The RJ45 hub connection should be wired to EIA/TIA568A
standard as shown.
The Cat5 connection from MCU to the AMR650-A should not
exceed 30 metres/100 feet.
2. The AMR650-A is then connected to the AMR650-P using either
Cat5e cable terminated at 8-way colour-coded punch down
connections (all 8 cores must be connected) or using a run of
standard speaker cable.
Only one method of connection between the active and passive
speaker is necessary.
Note: Use a professional quality punch down tool to ensure secure
punch down connections.
CONNECTING THE AMR650 V2.0
EIA / TIA 568A wiring standard
(view from contact end):
1 white/green
2 green
3 white/orange
4 blue
5 white/blue
6 orange
7 white/brown
8 brown
1
2 3 4 5 6 7 8
Cat5e cable terminated at AMR650
V2.0 8-way punch down connector:
1 white/brown
2 brown
3 white/blue
4 blue
5 white/green
6 green
7 white/orange
8 orange
MCU300
AMR650-P
Cat5/5e
AMR650-A
Cat5/5e (or standard
loud-speaker cable)
PSA65U