background image

 

 

 

 

 

Optronis CoaXPress Cameras 

 

 

CamPerform CP80 / CP90 Series 

 

 

 

 

 

 

 

User Manual 

 

 

CP80-3-M/C-540 
CP90-3-M/C-540 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Document Reference

 

1888-SU-01-I 

 

 

Release Date 

03/04/2018 

 

 

 

Summary of Contents for CP80-3-M/C-540

Page 1: ...Optronis CoaXPress Cameras CamPerform CP80 CP90 Series User Manual CP80 3 M C 540 CP90 3 M C 540 Document Reference 1888 SU 01 I Release Date 03 04 2018...

Page 2: ...our questions but should you have any further questions or if you wish to claim a service or warranty case please contact your local dealer or refer to the Optronis support You can contact our support...

Page 3: ...Model Description 11 3 1 1 Model Name and Options 11 3 1 1 CP80 CP90 Series Differences 11 3 2 Technical Data 12 3 2 1 General Info 12 3 2 2 Spectral Response 13 3 2 3 Glass Filter 13 3 2 4 Mechanica...

Page 4: ...Auxiliary Connector 23 5 1 5 CoaXPress Status LEDs 25 6 Camera Control Interface 26 6 1 GenICam XML Interface 26 6 1 1 CoaXPress GenICam Compliant Interface 26 6 1 2 XML Entry Access Mode 26 6 1 3 XM...

Page 5: ...ount option 14 Figure 8 CP90 Dimensions with F Mount option 14 Figure 9 Camera Single ROI Control 15 Figure 10 Sync Timings 18 Figure 11 CP80 HW Identification 21 Figure 12 CP90 HW Identification 21 F...

Page 6: ...6 1 General 1 1 Declaration of Conformity...

Page 7: ...ser manual to highlight some information Remarks and additional information Attention warnings 1 5 Scope of Delivery The camera is delivered together with Brief Introduction Available accessories are...

Page 8: ...e power over Coaxpress PoCXP or delivered external power supply option Temperature and Humidity Please respect recommended conditions You may use controlled airflow or heatsinks to keep camera in bett...

Page 9: ...alling or removing camera lens Depending on your lens mount type and lens pay attention to following points If your lens has a mounting mark first align lens holder and lens mounting marks and then ro...

Page 10: ...formula distances in millimeters mm Alternatively if you already have a lens you can compute working distance using above formula distances in millimeters mm Examples PixelSize 0 008mm Full resolution...

Page 11: ...l Number see Figure 4 Figure 3 Camera Model Name Decoder Figure 4 Camera Serial Number Decoder 3 1 1 CP80 CP90 Series Differences CP80 and CP90 series differ mainly by the user hardware interface Conn...

Page 12: ...lobal electronic shutter Trigger signal TTL 3 3 5 V 10 mA optically isolated Trigger modes internal free run external CXP Video Interface CoaxPress CXP6 CXP5 4 links Uplink Over CoaxPress Mounting Scr...

Page 13: ...ponse 3 2 3 Glass Filter Color cameras CP80 3 C 540 and CP90 3 C 540 models are delivered with an IR filter placed in front of the sensor Its typical transmittance is illustrated on Figure 6 Figure 6...

Page 14: ...ensions and Mounting Points 3 2 4 1 CP80 Mechanical Dimensions with F Mount FM option Figure 7 CP80 Dimensions with F Mount option 3 2 4 2 CP90 Mechanical Dimensions with F Mount FM option Figure 8 CP...

Page 15: ...graph Please check also 6 2 XML Main Entries Features Description page 28 paragraph to have a precise description of allowed values for each entry 4 1 Frame Format 4 1 1 Supported Pixel Formats The ca...

Page 16: ...an external signal to generate frames You must apply a TTL signal the Sync In input of the camera Please respect signal limits current and voltage and use the Aux to BNC adapter or respect Aux connec...

Page 17: ...lect the control source o Granularity On Same as in the Continuous mode camera register controls the exposure and can be modified using camera XML control interface o Granularity Off The exposure is c...

Page 18: ...Granularity is disabled Off o T2 is controlled by user external generator signal period o T1 is controlled by user external generator pulse width In both cases timings must be respected 4 4 1 3 Synchr...

Page 19: ...t frame rate and can be calculated using this formula _ _ _ 4 5 Sync Out Output The camera output Sync Out delivers a TTL signal reflecting camera frame acquisition External synchronization may be ope...

Page 20: ...7 Counter Information An optional counter information can be enabled When enabled this counter information is integrated in the first pixels of every transferred frame and replace the first 40 bits i...

Page 21: ...ure 12 CP90 HW Identification 5 1 2 Powering Camera Camera can be powered either by Power over Coaxpress PoCXP or using its external power connector 5 1 2 1 Using PoCXP When using PoCXP the power is s...

Page 22: ...irose HR10A 7R 4S Cable Connector Hirose HR10A 7R 4P Connector View Figure 13 CP80 Power Connector Connector View Figure 14 CP90 Power Connector Connector Pinout Connector Pinout Pin 1 VCC 24Volt 5 Ri...

Page 23: ...ctor LEMO FGG 0B 304 CLAD56Z Connector info Camera Aux connector type Hirose HR10A 7R 6S Cable Connector Hirose HR10A 7R 6P Connector View Figure 15 CP80 Auxiliary Connector Connector View Figure 16 C...

Page 24: ...r is negligible 0mA Easiest driver circuit is a transistor working in open collector configuration Figure 17 Sync In Input Schematics 5 1 4 2 Sync Out Sync Out has a built in 50 Ohm driver The output...

Page 25: ...wer Off System booting Solid orange or Led Chaser Powered but nothing connected only for power over power connector Slow pulse red Link detection in progress PoCXP active Fast flash green Link detecti...

Page 26: ...spond to a camera feature and use its own access type values ranges etc Paragraphs here after are explaining more in details how to use this XML file 6 1 2 XML Entry Access Mode Each XML entry have a...

Page 27: ...e sharing the same camera registers and use bit masking to access the dedicated bits These entries use XML parameters LSB and MSB to identify the right bits Example If an XML entry has Mask LSB 31 MSB...

Page 28: ...nning decimation or any other function changing the horizontal dimension of the image HeightMax 0x6004 RO Integer Mask LSB 15 MSB 0 Maximum height in pixels of the image This dimension is calculated a...

Page 29: ...e rate in Hz ExposureTime 0x60C8 RW Float Min 2 Max dynamic depends on other parameters Max available at address 0x60CC Sets the Exposure time in microseconds when ExposureMode is Timed This controls...

Page 30: ...RW Enumeration List CXP5_X4 CXP6_X4 CXP Bootstrap register ConnectionConfig ConnectionConfigDefault 0x4018 RO Integer CXP Bootstrap register ConnectionConfigDefault TapGeometry RO Enumeration List X1Y...

Page 31: ...f the updating process 1 If your software is out of date or if this is the first use Execute last version of Setup_UCXP_Flash_vx y z exe to install Firmware Update Software and Programming cable Drive...

Page 32: ...8 Update content H 29 01 2018 Update content New presentation and layout Synchronized content with datasheet v10 2016 8 2 Firmware Revision Firmware Revision Date Description v13 0 7 21 11 2017 Minor...

Reviews: