CP80-25-M/C-72
Ref. 1889-SU-01-D
Page 35
Access : RO
ExposureTime
Sets the Exposure time (in microseconds) when ExposureMode is Timed
Minimum : 98
Increment : 1
Maximum : ExposureTimeMax
Address : 0x6010 (for integer values), 0x60C8 (for floating values)
Length : 4
Access : RW
ExposureTimeMax
Maximum Exposure time (in microseconds) when ExposureMode is Timed
Address : : 0x60BC (for integer values), 0x60CC (for floating values)
Length : 4
Access : RO
GranularityMode
Write 0x01 to activate Granularity mode. In that mode, exposure time is set by
register (ExposureTime) when using external triggering or trigger over
CoaxPress
Write 0x00 to disactivate Granularity mode
Address : 0x6018
Length : 4
Mask : 0x0000FF00
Access : RW
ShutterMode
Select Global shutter mode or rolling shutter mode.
Warning : in rolling shutter mode, acquisition mode can only work in continuous
mode.
Write 0x01 to select Global shutter mode.
Write 0x00 to select Rolling shutter mode.
Address : 0x6180
Length : 4
Mask : 0x000000FF