background image

 

 

 

 
 

CamPerform  

CP80-25-M/C-72  

CoaxPress Camera 

 
 
 
 

 

 
 
 
 
 
 

User Manual 

 

Ref. 1889-SU-01-D 

Summary of Contents for CamPerform C-72

Page 1: ...CamPerform CP80 25 M C 72 CoaxPress Camera User Manual Ref 1889 SU 01 D...

Page 2: ......

Page 3: ...Minimum Frame rate internal synchronisation 15 Maximum Frame rate internal synchronisation 15 Max Frame Rate Examples 17 Calculation of Exposure Time 17 Frame Rate external synchronisation 18 Technic...

Page 4: ...CP80 25 M C 72 Ref 1889 SU 01 D Page 2 Gen i Cam 36...

Page 5: ...Firmware 8 0 Add offset and gain calibration menu in xml file Add Rolling shutter mode in the xml file Add of Granularity mode which allows to set exposure time through register when using external sy...

Page 6: ...ility that the following apparatus Product CP80 25 M 72 CP80 25 C 72 conform with the essential requirements of the EMC Directive 2004 108 EC based on the following specifications applied Specificatio...

Page 7: ...cable Programming cable USB2 for firmware update User Manual CD ROM Optronis customer service Optronis GmbH Ludwigstr 2 77694 Kehl Germany Tel 49 0 7851 9126 0 Fax 49 0 7851 9126 10 E mail info optro...

Page 8: ...ver CoaxPress or as an option the CP80 25 M C 72 camera power supply not included in shipment Environmental Conditions Temperature range during operation 45 C housing temperature 0 C ambient temperatu...

Page 9: ...e protected from dirt dust grease and water Make sure that all the connecting cables are in good condition Defective cables have to be replaced Always unplug the camera before cleaning it Do not use c...

Page 10: ...5 M C 72 Ref 1889 SU 01 D Page 8 Camera 1 Camera housing 2 Mounting holes 2x M4x6mm 1x x6mm 3 Lens mount Nikon F 4 Nikon lens 5 electrical interface right side 6 Mounting holes 4x M4x6mm 1 3 4 5 6 2 4...

Page 11: ...nnel 2 Power Connector 3 Auxiliary Connector 4 Indicator Lamp LED Electrical Interface Auxiliary Aux connector pinout Auxiliary Aux connector pinout Pin Nr Description 1 Sync In External Synchronisati...

Page 12: ...rcuit is a Transistor working in open collector configuration SyncIn input voltage limit ranges from 5 Volts to 30 Volts Voltages applied beyond these limits may damage the SyncIn Input SyncOut has a...

Page 13: ...de view Camera Pwr connector type Lemo EGG 0B 303CLL Cable Connector Lemo FGG0B303 CLAD56Z Power Pwr connector pinout Pin Nr Description 1 VCC DC Power 24Volt 5 Ripple 200mV Inrush Current 0 6A 2 GND...

Page 14: ...ed Slow pulse green Camera connected waiting for event e g trigger exposure pulse Slow pulse orange Camera connected transferring frames Solid green Error during data transfer 500ms red pulse System e...

Page 15: ...e lens holder in a way that the back surface of the lens is completely attached to the surface of the lens holder The lens reference has to be positioned in face to the lens holder reference as shown...

Page 16: ...s pull back first the silver clip in order to unlock the lens as shown below Then the silver clip has still to be pulled back turn the lens clockwise until the lens is unmounted completely lens refere...

Page 17: ...rmance excellent image quality excellent sensitivity low noise monochrome and color internal and external synchronisation Region of Interest ROI Frame format The Frame format frame resolution of the c...

Page 18: ...m frame interval maximum frame rate that can be reached by the camera internal synchronisation mode depends on the CoaxPress Speed Bit Rate Compliance labeling Bit Rate Gbps Maximum frame rate CXP6 6...

Page 19: ...72 CXP6 BNC 4x 4096 4096 112 CXP6 BNC 4x 2048 2048 277 CXP6 BNC 4x 1024 1024 531 CXP6 BNC 4x 256 256 1688 Max Frame Rate values are rounded values Calculation of Maximum Frame Rate at CXP6 BNC 4x 1000...

Page 20: ...he external synchronisation timing for more information about resulting frame rates and exposure times Alternatively SyncIn can be applied directly between Pin 1 and Pin 3 on the camera power Pwr conn...

Page 21: ...4 5 m Acitve area 23 04 mm x 23 04 mm Sensor responsitivity 3 3 Volt lux s Sensor S N ratio 53 dB Linear Shutter Global efficiency 99 9 Minimum Ambient Temperature 0 C Maximum Housing Temperature 45 C...

Page 22: ...CP80 25 M C 72 Ref 1889 SU 01 D Page 20 Spectral Response Transmittance Spectral response Monochrome Color Sensor...

Page 23: ...CP80 25 M C 72 Ref 1889 SU 01 D Page 21 Mechanical Dimensions F Mount Lens CM...

Page 24: ...CP80 25 M C 72 Ref 1889 SU 01 D Page 22 Figure Side View all dimensions in mm Screw threads in socket M4 min 6 mm depth 1 x min 6 mm depth in the middle...

Page 25: ...P80 25 M C 72 Ref 1889 SU 01 D Page 23 Synchronisation Input schematics Figure SyncIn Schematics for illustration only Synchronisation Output schematics Figure SyncOut Schematics for illustration only...

Page 26: ...U 01 D Page 24 Internal Synchronisation Timing T1 Exposure time selected by software T2 Frame Interval 1 Frame Rate selected by software Synchronisation Output Logic 1 during Exposure Time T1 Internal...

Page 27: ...the sensor depends on frame format and Camera Link mode T1 T3 T1 T3 T1 max no limit 1sec recommended due to shutter T2 max no limit 1sec recommended due to shutter efficiency and thermal noise T2 min...

Page 28: ...ns to object in mm B Size of the object in mm Example A Distance from lens to object 300 mm B Object Size 100 mm calculated focal length 300 1 100 32 583 73 7 mm Reduced Sensor Resolution At reduced s...

Page 29: ...has to be changed as follows at a focal length of 35mm an object size of 100mm and a sensor size of 15 4mm the new distance from lens to object is calculated as 35 1 100 9 9 388 mm The distance from...

Page 30: ...ated as follows Example Sensor Size as calculated above 9 9mm required Object Size 9 9mm The required magnification factor is 1 1 focal length of the lens 35mm calculated Length of the Distance Washer...

Page 31: ...delivered with the camera Please go through the following steps 1 Switch OFF camera 2 Connect USB cable to PC and camera Aux input 3 Install USB driver on PC if it is not already done To install USB d...

Page 32: ...CP80 25 M C 72 Ref 1889 SU 01 D Page 30 6 Click on Exit 7 Switch OFF camera and switch ON camera...

Page 33: ...VendorName Name of the manufacturer of the device Address 0x2000 Length 32 Access RO DeviceModelName This feature provides the model of the device Address 0x2020 Length 32 Access RO DeviceManufacturer...

Page 34: ...Address 0x4000 Length 4 Access RW WidthMax Maximum width in pixels of the image Address 0x6000 Length 4 Mask 0xFFFF0000 Access RO Width This feature represents the actual image width expelled by the c...

Page 35: ...in to the area of interest in pixels Minimum 0 Increment 256 Maximum WidthMax Width Address 0x60D0 Length 4 Access RW OffsetY Vertical offset from the origin to the area of interest in pixels Minimum...

Page 36: ...th 4 Mask 0x000000FF Access RW AcquisitionStart This feature starts the Acquisition of the device Write 0x01 to start acquisition Write 0x00 to stop acquisition Address 0x601C Length 4 Mask 0x000000FF...

Page 37: ...CC for floating values Length 4 Access RO GranularityMode Write 0x01 to activate Granularity mode In that mode exposure time is set by register ExposureTime when using external triggering or trigger o...

Page 38: ...e disables the flash configuration load at the camera boot IndicatorLamps Switch ON OFF indicator lamps Write 0x00 to switch ON the indicator lamps Write 0x01 to switch OFF the indicator lamps Address...

Page 39: ...CP80 25 M C 72 Ref 1889 SU 01 D Page 37...