2.3.3
Connecting the Parameter Setting Terminal
The pin specifications for the OTS system console port are shown in 2.3.4 and RS-232 cable connection examples are
shown in 2.3.5 and 2.3.6. The console port is a DTE (male) DB-9 connector.
2.3.4
Console Port Pin Specifications
3
Stop bit
1 bit
4
Parity
None
5
Flow control
None
6
Baud rate
9600 bit/s
7
RS, ER
Always ON
8
CD
Not monitored
9
Terminal connection cable
RS-232 cable (cross)
However, a DB-9 female connector should be used
on the OTS series side.
Pin No.
Signal name
Signal contents
Remarks
1
Not connected
2
RD
Receive data
Input
3
TD
Send data
Output
4
Connected to pin 6
5
SG
Circuit ground
6
Connected to pin 4
7
Connected to pin 8
8
Connected to pin 7
9
Not connected