HD71/HD710/HD75
Confidential
4-1
Chapter 4
Function Test & Alignment Procedure
4-1 Test Equipment Needed
- IBM PC with XGA resolution
- DVD player with Multi-system, equipped “Component”, “S-Video” ,
“Composite” and "HDMI."
- HDTV Source (480P, 720P, 1080i)
- Minolta CL-100
- Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
- After changing parts, check the information below.
4-2 Service Mode
1. Turn on the projector
2. Do the following actions sequentially to enter service mode menu
(1) Press “Power”, “Source”, “Source” and “Up” button sequentially.
(2) Service Mode will be shown.
(3) Choose “Exit” to leave the Service Mode after all.
4-3 OSD Reset
1. After final QC step, we have to erase all saved change again and restore the OSD
default setting. The following actions will allow you to erase all end-users' settings and
restore the default setting:
(1) Please enter OSD menu.
(2) To execute "Reset" function.
Summary of Contents for HD71
Page 65: ...HD71 HD710 HD75 Confidential I Appendix A D C HD71 HD710 HD75...
Page 68: ...HD71 HD710 HD75 Confidential IV Assy Tpye A Engine Module HD71 HD710 HD75...
Page 70: ...HD71 HD710 HD75 Confidential VI Assy MB PCBA HD71 HD710 HD75...
Page 71: ...HD71 HD710 HD75 Confidential VII...
Page 73: ...HD71 HD710 HD75 Confidential IX Assy Top Cover HD71 HD710 HD75...
Page 75: ...HD71 HD710 HD75 Confidential XI Assy Bottom Cover HD71 HD710 HD75 9...
Page 80: ...HD71 HD710 HD75 Confidential XVI Assy Lamp Drive OSRAM 230W HD71 HD710 HD75...
Page 84: ...HD71 HD710 HD75 Confidential XX Assy Engine Module 720P 200W A19 HD71 HD710 HD75 20...
Page 88: ...HD71 HD710 HD75 Confidential XXIV D P HD71 HD710 HD75 PC Packing Procedure Drawing 33...