Confidential
4-
EW610ST/EX610ST/EW605ST/EX605ST
4-4 Test Condition
(This section links to common
This section links to common
service manual 4-4 Test Condition)
Defect specification table
For EX610ST/EX605ST
Order
Symptom
Pattern
Criteria
1
Bright pixel ( dots)
Gray 10 pattern
A+B=0
2
Dark pixel(dots)
White pattern
A+B≤4
Unstable pixel (dots)
Any pattern
A+B=0
4
Adjacent dark pixel (dots)
Any pattern
A+B=0
5
Dark blemish (Dirty)
Blue 60 pattern
A+B≤2
(diameter <1/2 inch)
6
Bright blemish (Dirty)
Gray 10 pattern
A+B≤2
(diameter <1/2 inch)
7
Bright dots on frame
Gray 10 pattern
≤1
For EW610ST/EW605ST
Order
Symptom
Pattern
Criteria
1
Bright pixel ( dots)
Gray 10 pattern
A+B=0
2
Dark pixel(dots)
White pattern
A+B≤7
Unstable pixel (dots)
Any pattern
A+B=0
4
Adjacent dark pixel (dots)
Any pattern
A+B=0
5
Dark blemish (Dirty)
Blue 60 pattern
A+B≤4
(diameter <1 inch)
6
Bright blemish (Dirty)
Gray 10 pattern
A+B≤4
(diameter <1 inch)
7
Bright dots on frame
Gray 10 pattern
≤1
Summary of Contents for EW605ST
Page 43: ...EW610ST EX610ST EW605ST EX605ST Confidential Assy Engine Module 34 ...
Page 47: ...EW610ST EX610ST EW605ST EX605ST Confidential Assy Top Cover Module ...
Page 49: ...EW610ST EX610ST EW605ST EX605ST Confidential Assy Lamp Module ...
Page 51: ...EW610ST EX610ST EW605ST EX605ST Confidential 11 Assy Main Board Module ...
Page 53: ...EW610ST EX610ST EW605ST EX605ST Confidential 13 Assy Bottom Cover Module ...
Page 55: ...EW610ST EX610ST EW605ST EX605ST Confidential 15 AK ...