EP780
3-
Confidential
3-2 Main Procedure
No
Symptom
Procedure
No Power
- Ensure the Power Cord and AC Power Outlet are securely connected
- Check Lamp Cover and Interrupt Switch
- Ensure all connectors are securely connected and aren’t broken
- Check DC-DC
- Check Ballast
- Check Main Board
Auto Shut Down
- Check LED Status
a. Lamp LED Light
- Check Lamp
- Check Lamp Driver
- Check Main Board
b. Temp LED Light
- Check Thermal Sensor
- Check Thermal Switch
- Check Fan
c. Tem LED Blinking
- Check Fan
- Check Main Board
d. No Power
- Refer to “No Power” troubleshooting
3
No Image
- Ensure the Signal Cable and Source work as well
(If you connect multiple sources at the same time, use the “Source”
button on the control panel to swtich)
- Ensure all connectors are securely connected and aren’t broken
- Check Main Board
- Check DMD Board
- Check DMD Chip
4
No Light On
- Ensure all connectors are securely connected and aren’t broken
- Check Lamp Module
- Check DC-DC
- Check Ballast
- Check Main Board
5
Mechanical Noise
- Check Color Wheel
- Check Fan Module
6
Line Bar / Line
Defect
- Sometimes it’s because of the DMD Chip and the DMD Board did
not assemble properly
- Check DMD Board
- Check DMD Chip
- Check Main Board
All manuals and user guides at all-guides.com